background image

MS 104/5

 

ML46758, Rev. 01

 

June 2002

 

Troubleshooting 

The troubleshooting procedure is given in 

Table 3

. Read the entries in the 

column 

Problem

 until you reach the problem that applies to the MS 104/5. Then 

perform the corrective action(s) appearing in the same row. If the problem 
persists, note the status of all the LEDs and consult your 

MRV

 representative. 

Table 3:  Startup and Operation Troubleshooting 

No 

Problem 

Probable Cause 

Corrective Action 

1 PWR

 LED off 

No line (mains) power. 

1.  Check power cord 

connection. 

2.  Check line (mains) power 

wall outlet. 

3.  Check power cord. 

Fiberoptic port

 L

 LED off 

No link on fiberoptic cable. 

1.  Check fiberoptic cable 

connections. 

2.  Check device at other end 

of fiberoptic cable. 

3.  Check fiberoptic cable. 

4.  Clean connectors as 

described in Appendix B:  
Cleaning Optical 
Connectors. 

Copper port

 L

 LED off 

Bad STP/UTP cable connection. 

1.  Check electrical cable 

connections. 

2.  Check device at other end 

of electrical cable. 

3.  Check electrical cable. 

Fiberoptic port 
performance lower than 
expected 

Duplexity mismatch. 

Ensure that the port and co-port 
are set to the same duplexity. 

Copper port performance 
lower than expected 

Device connected to this port is 

not

 auto-negotiating and is 

operating in full-duplex mode. 

Set DIP switch AUTO toggle 
and 10/100 toggle associated 
with the MS 104/5 port are set 
to down position. 

PRI LED off. 

Link to P1 SEC port active, i.e., 
SEC LED on. 

1.  Check fiberoptic cable 

connections to the P1 PRI 
ports (TX, RX). 

2.  Check fiberoptic cable. 

3.  Clean connectors as 

described in Appendix B:  
Cleaning Optical 
Connectors. 

 

 

13

 

 

Содержание MS 104

Страница 1: ...MS 104 5 Ethernet Switches User Manual MRV Communications Inc URL http www mrv com...

Страница 2: ...the use of the contents of this document since the customer bears sole responsibility Trademarks All trademarks are the property of their respective holders Copyright 2002 by MRV All rights reserved N...

Страница 3: ...ations 6 Features 6 Available 6 Optional 7 Layout 8 Front View 8 Ports 9 DIP Switch 9 LED Indicators 11 Installation and Setup 12 Package Contents 12 Procedure 12 Operation 12 Troubleshooting 13 Produ...

Страница 4: ...s of the MS 104 and MS 105 6 Figure 2 MS 104F2 8 Figure 3 MS 105F 8 Figure 4 MS 105FR 8 Figure 5 Interconnection of MS 104 5 and another Device 12 Tables Table 1 DIP Switch Setting 9 Table 2 Front Pan...

Страница 5: ...ess Control MDI Media Dependent Interface MM MultiMode SM SingleMode ToS Type of Service Safety Requirements Caution To reduce risk of electrical shock and fire and to maintain proper operation ensure...

Страница 6: ...whether it is a runt jabber or CRC error packet and discarding it if it is so Auto Negotation or Auto Sensing Automatic self reconfiguration capability of the 10BASE T 100BASE TX switching ports to o...

Страница 7: ...nly send and receive unicast packets to each other Optional Packet Prioritization Assignment of high or low processing priority to a packet on the basis of Port VLAN or ToS Flow Control Forcing of the...

Страница 8: ...002 As another example ports P1 and P3 can be put in one group ports P2 and P4 in another Layout Front View Following are the front views of the MS 104F2 MS 105F and MS 105FR Figure 2 MS 104F2 Figure...

Страница 9: ...s marked AUTO 10 100 and FD HD AUTO designates auto negotiation 10 100 designates 10 100 Mbps data rate FD HD designates full duplex half duplex Each toggle marked with a number e g 2 3 4 or 5 is func...

Страница 10: ...ive only if Auto negotiation DIP switch toggle 4 position is down i e if auto negotiation is disabled UP Set Port 2 to operate in Half Duplex mode Effective only if Auto negotiation DIP switch toggle...

Страница 11: ...FF Port P 3 link absent or faulty ON Port P 3 activity present P3 A OFF Port P 3 activity absent ON Port P 4 link OK P4 L OFF Port P 4 link absent or faulty ON Port P 4 activity present P4 A OFF Port...

Страница 12: ...nel Note If the device port to which the MS 104 5 electrical data port is connected does not have auto negotiation capability the MS 104 5 port operates in half duplex mode and at the same speed of th...

Страница 13: ...nd of fiberoptic cable 3 Check fiberoptic cable 4 Clean connectors as described in Appendix B Cleaning Optical Connectors 3 Copper port L LED off Bad STP UTP cable connection 1 Check electrical cable...

Страница 14: ...er Budget 9 dB to 24 dB model dependent see Appendix A Models Electrical Data Port Supported Speeds Connector Type Connector Pinout MDI X MDI 10 and 100 Mbps RJ45 8 pin shielded female 1 Tx 2 Tx 3 Rx...

Страница 15: ...s one redundant 100BaseFX port switch MM 1310nm 0 2km DSC MS105FR MT M 4 10 100BaseTX ports one redundant 100BaseFX port MM 1310nm 0 2km MT RJ MS105FR S1 4 10 100BaseTX ports one redundant 100BaseFX p...

Страница 16: ...mination Isopropyl alcohol Solvent for contaminants Tissues Soft multi layered fabric made from non recycled cellulose Procedure The procedure for cleaning connectors is as follows 1 If no stains are...

Отзывы: