MRU GmbH
USER MANUAL OPTIMA 7 - NDIR
50
15.1 Lambda (Brettschneider formula)
The emission analyser OPTIMA7-NDIR is a multi-component analyser,
which measures contin-
uously:
CO (carbon monoxide) [%] O
2
(oxygen) [%]
CO
2
(carbon dioxide) [%] NO (nitrogen monoxide) [ppm]
HC (hydrocarbons) [ppm]
Simplified Excess Air calculation according to Brettschneider :
15.2 P.E.F. factor
The P.E.F factor Propane-Hexane is the conversion factor and is used because the OPTIMA7-
NDIR is calibrated with propane (C
3
H
8
), but it has to display n-Hexane.
n-Hexane = P.E.F. * propane
This factor is determined for this in the factory and used in the calculation, display and printout.
This determines value is displayed in the service-menu and after the adjustment.