background image

CONTENTS

Product Overview

Safety Precautions

Product Introduction

Product Use

Introduction and Use of Level Meter

Maintenance and Servicing

Common Problems

Packing List

1

3

4

9

13

17

19

20

3

2

Dear user of 

MRC

 Hello! Thank you for choosing 

MRC

 Self-pressurized Series for LN2 Storage and

 Supply (hereinafter referred to as “the Product”). Please read and follow the
 Instructions strictly and keep it properly, to better understand the Instructions, well use

!the Product and avoid personal injuries or property losses

The Product is a cryogenic vessel. User is recommended to assign specific person to master 
the Instructions and operate the Product as specified.
Organize safety education to relevant personnel regularly to avoid losses due to misoperation.
It is forbidden to overfill the Product. It should reach the lower edge of neck tube as the optimal 
injection volume.
The pipeline connecting the liquid nitrogen container to the outside must be firm to prevent the 
occurrence of liquid nitrogen leaking, dripping, splashing and other phenomena to ensure the 
safety of the operator.
After use of the Self-pressurized Series tank, the inlet valve must be closed. 
The bottom of the container is equipped with four high-strength casters, which is convenient for 
short-distance movement of the container. When moving, care should be taken, and it must not 
be pushed or moved violently to prevent collision. It is strictly forbidden to move on uneven 
ground.
Transfer the Product with care to avoid overflow and splashing.
It is forbidden to contain any other low-temperature or high-temperature medium other than liquid 
nitrogen; otherwise, quality warranty will expire!
Avoid skin exposure and take proper protection measures, such as low-temperature gloves and 
goggles, while handling the Product due to its ultralow temperature (-195.8

). Do not wear boots 

to avoid cold injury when liquid nitrogen drops in the boots.
Do not touch the container opening of liquid nitrogen due to low temperature.
It is forbidden to block the container opening that has liquid nitrogen; otherwise, pressurization 
and explosion may occur!

SAFETY PRECAUTIONS

WARNING

ATTENTION

Violation may lead to major casualties!

Actions or operations which 

must be prohibited 

Actions or operations which 

must be followed

Violation may lead to personal casualties, 

container damage and property loss!

Содержание YDZ-100K

Страница 1: ...leasereadthis instruction carefully before us The company reserves the right to explain the instructions The appearance of the product is subject to the actual product Please keep the invoice together after reading No further notice in case of product technology or software upgrad 2 06 A ...

Страница 2: ...uid nitrogen filling port or the level meter to fill the drain port of the liquid nitrogen machine fractionating tower or the pipe 2 The container adopts the boosting method of applying a pressure to the liner after vaporization of a little liquid nitrogen which has the advantages of convenient operation and rapid boosting and guarantees the purity of liquid nitrogen 3 The container has high stren...

Страница 3: ...operator After use of the Self pressurized Series tank the inlet valve must be closed The bottom of the container is equipped with four high strength casters which is convenient for short distance movement of the container When moving care should be taken and it must not be pushed or moved violently to prevent collision It is strictly forbidden to move on uneven ground Transfer the Product with ca...

Страница 4: ...urface transfer away the sample immediately otherwise the sample can be damaged We bear liability for product loss only and not bear the liability of the third party The container mainly comprises a shell a liner swivel casters drain pipes various valves pressure gauges vacuum sealing joints etc see Fig 1 Fig 2 and Fig 3 For any quality issue please return the Product to the Company for inspection...

Страница 5: ...xhaust valve must be opened for venting and pressure relief When the container is out of use this valve shall not be opened Pressure increasing valve When it is opened the pressure of the liner will rise When it is out of use it shall be closed tightly Pressure gauge It is used to indicate the pressure of the liner Liquid inlet outlet valve It shall be connected with the liquid hose to fill liquid...

Страница 6: ... vacuum sealing joints have been sealed before the products are delivered out of the factory and protected by vacuum sealing joint hoods and it is strictly prohibited to remove the vacuum sealing joint hoods privately The container is installed with a safety valve The set pressure of the safety valve has been adjusted before delivery out of the factory The user shall not disassemble it in use If i...

Страница 7: ... it is required to convey liquid nitrogen all exhaust valves must be open 3 Product Operation and Use ATTENTION After the pressure increasing valve is opened usually the lower part of the shell is frosted which is the normal phenomenon when the container is working When the container is fully filled with liquid nitrogen but a gas phase space equal to 10 of the geometric volume of the container is ...

Страница 8: ...e Medium and long distance transport No liquid nitrogen is stored 4 Test and Calculation Method of Daily Evaporation Rate of Product Note The daily evaporation rate of the product shall be tested according to GB T 18443 5 2010 When the ambient temperature and the atmospheric pressure are not tested according to the above regulations or the minimum division value of the measuring instrument is diff...

Страница 9: ...ing rod Lower ring connecting rod Measuring rod Power supply 3 6V lithium battery power supply average working current about 15uA Effective liquid level measuring range of sensor 200mm 1000mm Diameter of sensor rod Φ12mm Operating humidity range relative humidity 0 80 Measuring accuracy 1 Working pressure 0 0 6MPa Measuring medium liquid nitrogen Sleeve the PTFE flat seal gasket into the sensor an...

Страница 10: ...rd of the current level meter Long press S to display It indicates setting the capacitor value when the current level meter doesn t contact liquid nitrogen Long press S to display It indicates setting the capacitance value when the test range length of the current level meter the upper hole of the level meter is completely soaked in liquid nitrogen Alarm and faults of liquid level detection alarm ...

Страница 11: ... ice and can t increase the pressure the following ice melting measures can be taken Adopt the air pressure method to eliminate the residual liquid nitrogen in the container The method is as follows Screw the lock nut at the top of the valve seat tightly close the pressure increasing valve open the liquid inlet outlet valve and the exhaust valve and use nitrogen or dry gas do not use oxygen or any...

Страница 12: ...ayer infusion hose Product Instructions PTFE sealing gasket Item Type Item Type Regular Model Qty Qty Unit Unit Remarks Remarks Including locking nuts and pressure stabilizers Standard Standard Standard One piece is equipped and one piece is standby 1 1 1 1 2 K Series Products YDZ 5 15 30 50 are equipped with lock nuts while the regular models YDZ 100K 150 200K 240 300 500 are equipped with float ...