background image

Terms and Conditions

 

Congratulations!

 

You are now the owner of a new 

IR-CAM-FEVER 

world class thermal imaging device which includes 

hardware and software components (the “Product”).

 

PLEASE READ THIS DOCUMENT CAREFULLY;

 

1. 

GENERAL. 

This document represents our entire understanding with respect to its subject matter and 

supersedes any previous communication or agreements that may exist. Modifications to this document will 
be made only through a written amendment signed by both parties. This document will be governed by the 
exclusive laws of the state of Israel, excluding rules as to choice and conflict of law. The courts of Israel will 
have exclusive jurisdiction over all claims arising out of or relating

 

to this document, and you hereby consent and submit to such exclusive jurisdiction. It is agreed that the 
United Nations Convention on Contracts for the International Sale of Goods will not apply. Judgments of 
the foregoing courts will be enforceable in any country.

 

 

PRODUCT USAGE NOTICES

 

Attachment to your Mobile Device

 

To avoid damage to your Product and mobile device, attachment of the Product to your mobile device 
should be done with care, securing the locking knob with your fingers only. Do not use any external tools 
as too much pressure may mark or damage your mobile device.

 

Calibration

 

The Product makes use of specific calibration data, which was prepared for it in the factory. It is possible 
that during prolonged field usage of the Product a deterioration of image will be noticed. In such case we 
recommend that you send in the device, for re-calibration at the factory. Please contact our support team 
for further instructions.

 

Accuracy

 

For most accurate temperature measurement results, we recommend that you wait 8-10 minutes after 
you have started the Product before measuring a temperature.

 

Содержание IR-CAM-FEVER

Страница 1: ...Quick Start Guide Congratulations on purchasing IR CAM FEVER for Thermography The thermography camera that is changing the way thermal imaging technology works...

Страница 2: ...be connected to the single board computer SBC through the USB cable The application that runs the IR CAM FEVER is preinstalled on the SBC Connect the SBC to a monitor through the HDMI plug and a mouse...

Страница 3: ...pplication would be sent to you Compatibility The IR CAM FEVER calibration tables are pre installed on the SBC if you change the SBC connect the SBC to an ethernet connection plug in the IR CAM FEVER...

Страница 4: ...een to the HDMI port 3 Turn on the SBC With the cable supplied connect the IR CAM FEVER USB OTG micro USB connection to the IR CAM FEVER device 5 and the USB to the SBC 4 The IR CAM FEVER application...

Страница 5: ...Application Overview Settings Menu Quick Access Menu Temperature Range Lock Buttons Temperature Scale Gallery Image Recording Video Recording IR CAM FEVER...

Страница 6: ...perature range press the current temperature and then press the button on the dial For best performance the ambient room temperature should be 25 C Foroptimalperformancewaitbetween8 10minutesfromstart...

Страница 7: ...horoughly with a thermometer The IR CAM FEVER is affected by the ambient temperature of its surroundings and it provides relative temperature readings as opposed to a thermometer which gives absolute...

Страница 8: ...een This will open the settings menu Click on General Settings Ensure Time lapse is on Disable The orientation of the video or snapshot can be also be amended from the General Settings menu by clickin...

Страница 9: ...e the settings are as follows Check Play alert for the alert sound Detection duration is 0 seconds Alert delay is 0 seconds Recording time after detection is 1 minute These parameters can be changed b...

Страница 10: ...aphy Configuring the Emissivity Click on the Quick Access Menu Click on the Ruler and then on Emissivity Using the or symbols change the Emissivity value to 0 98 This can also be done using the on scr...

Страница 11: ...t A box will appear on the screen with small circles on each corner Click and drag the box to the area of interest Click and drag the corners of the box to resize the area of interest Click the flame...

Страница 12: ...temperature a thermal imager will show the temperature in relative terms As in what is my temperature relative to the person next to me To do this we need to establish the baseline temperature either...

Страница 13: ...the temperature and recalibrate the threshold accordingly Also since the ambient temperature changes during the day it is recommended to repeat the process once every 8 hours Can the IR CAM FEVER be...

Страница 14: ...the United Nations Convention on Contracts for the International Sale of Goods will not apply Judgments of the foregoing courts will be enforceable in any country PRODUCT USAGE NOTICES Attachment to...

Страница 15: ...in a residential installation This Product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to rad...

Страница 16: ...for example products that emit laser radiation or the sun This can have unwanted effect on the performance of the Product It can also cause damage to the detector WARNING Do not use the Product in a...

Страница 17: ...nt damage Replacement of lens should be done in a dry area using clean hands with maximum care WARNING Do not use pressurized air from pneumatic air circuits in a workshop to remove dust from the dete...

Отзывы: