Generator
Model
MS90-MS400
SAH3000-SAH6000
Super1-Super3
MX4-MX6
Installer and Home Owner Section
Linear Steam Head
6
®
®
NOTE:
Drawings are for illustrative purposes only.
Consult with qualified designer, architect or contractor for steam room construction.
Model 104480
Steam Emission Zone
The Steam Emission Zone is the area in front of the steam head that contains dense, hot steam as it exits the steam head.
Steam dissipates as it moves away from the steam head, and becomes less hot. The steam zone is the area where contact with
steam presentees a scalding hazard. The steam head must be installed in a location to ensure that a steam bather will not be
near the steam emission zone. The diverter reduces the steam emisson zone.
Steam
Emission
Without
Diverter
Steam
Emisson Zone
With
Diverter
Steam Room
Interior
Steam Room
Interior
Steam
Emission
Steam Head without Optional Diverter
Steam Head with Optional Diverter
6”-12”
Above Floor
6”-12”
Above Floor
Steam
Emission Zone
Minimum # of
Linear Steam
Heads
1
1
2
Steam Emission
Zone
with Diverter
2”
2”
2”
Steam Emission
Zone
without Diverter
10”
24”
24”
Finished
Wall
Finished
Wall
The steam emission zone may vary with each installation.
Always test the steam emission zone to insure safety.
20
Содержание 104480
Страница 13: ...Installation Operation Maintenance Manual AromaSteam SteamHead mr steam Feel Good Inc PUR100421 Rev 5 22...
Страница 26: ...Installation Operation Maintenance Manual SteamLinx mr steam Feel Good Inc PUR100518 Rev 5 22...
Страница 29: ...Installation Operation Maintenance Manual S Su e Auto u mr steam Feel Good Inc PUR100200E Rev 5 22...
Страница 32: ...Installation Operation Maintenance Manual MX AutoFlush mr steam Feel Good Inc PUR100532 Rev 5 22...
Страница 35: ...Installation Operation Maintenance Manual Condensation Pan mr steam Feel Good Inc TS0012 Rev 5 22...