Mr. Heater HST45 Скачать руководство пользователя страница 7

7

Operating Instructions and Owner’s Manual

Mr. Heater | Gas-Fired Low-Intensity Infrared Heater

 

ATTENTION

  Risque de monoxyde de carbone
  L echappement du radiateur doit s’effectuer a l’exterieur.
  Utillisez le materiel fourni.
  Le non-respect de ces consignes peut entrainer mort ou 

blessures.

Venting Codes

The location, size, installation and termination of vents, as well as 
the minimum required safe distances when penetrating combustible 
walls, must comply with local codes and recommendations of the 

local gas company. 

United States:

 Refer to National Fuel Gas Code, 

ANSI Z223.1 – latest revision, (same as NFPA Bulletin 54). 

Canada: 

Refer to Can 1-B149.1 : Installation Codes for Gas Burning Appliance.

 
Non-residential Installations:

 

Aircraft Hangars

The MHT tube heater may be used in certain areas of aircraft 
hangars. Installation in aircraft hangars must be in accordance with 
the following codes: United States: Refer to Standard for Aircraft 
Hangars, ANSI/NFPA-409 – latest revision. Canada: Refer to Standard 
CGA B149-1M91.

Heaters in aircraft storage or service areas must be installed a 
minimum of 10 feet above the upper surface of wings or engine 
enclosures of the highest aircraft which may be housed in the 
hangar. (This should be measured from the bottom of the heater to 
the top of the wing, or engine enclosure, whichever is highest from 

the floor).

In other sections of aircraft hangars, such as shops or office, heaters 
must be installed a minimum of 8 feet above the floor.

Heaters installed in aircraft hangars shall be located so as not to be 
subject to damage by aircraft, cranes, movable scaffolding or other 
objects.

When installed over hoists, the minimum required safe distances to 
combustibles must be maintained from the uppermost point of the 
combustible materials placed on the hoist.

 

 

public Garages

The MHT tube heater may be used in public garages. Installation 
in public garages must be in accordance with the following codes: 
United States: Standard for Parking Structures NFPA-88A – Latest 
revision, or the Standard for Repair Garages, NFPA-88B – latest 
revision. Canada: Refer to Can 1-B149.1: Installation Codes for Gas 

Burning Appliances.

Heaters must be installed a minimum of eight feet above the 
floor. Minimum required safe distances to combustibles must be 
maintained from vehicles parked below the heater.

When installed over hoists, the minimum required safe distances to 
combustible must be maintained from the uppermost point of the 
combustible materials placed on the hoist.

 

 

Hazardous Locations

Where there is the possibility of exposure to combustible airborne 

material or vapor, consult the local Fire Marshal, the Fire Insurance 

Carrier or other authorities for approval of the proposed installation.

Electrical Service Requirements: 

System Requirements

The MHT tube heater requires a grounded three-prong electrical 
outlet to be installed within 18 inches of the rear surface of the 
heater’s burner box. It is recommended that the outlet for the heater 
be ceiling-mounted and should be on a dedicated circuit. 

DO NOT

 

use an electrical extension cord to operate the heater.

 

Heater Rating: 120 VAC, 60 Hz, Single phase, 1 Amp

 

 

WARNING

  Electrical Shock Hazard
  Plug heater into grounded three-prong ceiling receptacle.
  Do not cut or remove the grounding prong from this plug.
  Do not use with an extension cord.
  Failure to follow these instructions will result in death or 

electrical shock.

 

 

ATTENTION

  Risque d’electrocution
  Brancher le cordon du radiateur sur un socie a 3 broches 

et a la masse, situe au plafond.

  Ne pas sectionner ou retirer la broche de masse de cette 

prise.

  N’utilliser aucun cable de rallonge.
  Le non-respect de ces consignes peut entrainer mort ou 

electrocution.

Grounding

The heater must be electrically grounded in accordance with the 
following codes: 

United States:

 Refer to National Electrical Code 

ANSI/NFPA-70 – latest revision. Wiring must conform to the most 
current National Electrical Code and local ordinances. 

Canada:

 Refer 

to Canadian Electrical Code, CSA C22.1 Part 1 – latest revision.

 

Venting Requirements:

 

System Requirements

The MHT tube  heater must be installed with venting or with one 
of the optional venting kits available from Enerco. 

DO NOT

 connect 

this heater to a separate chimney. Gas appliances must not be 

connected to a chimney flue serving a seperate solid-fuel burning 

appliance. 

DO NOT

 common vent with any other fuel burning 

appliance.

 

Maximum Length:

 25 feet  

 

Minimum Length:

 5 feet

 

 

WARNING

  Carbon Monoxide Hazard
  Heater must be exhausted outside.
  Use materials supplied.
  Failure to follow these instructions will result in death or 

injury.

Содержание HST45

Страница 1: ...any electrical switch do not use any phone in your building supplier If you cannot reach your gas supplier call the Fire Department Gas Fired Low Intensity Infrared Heaters approved for residential Ga...

Страница 2: ...Echec pour se conformer aux precautions et aux in structions a fourni avec cet appareil de chauffage avoir pour resultat la mort blessure et la perte de propriete ou les dommages physiques serieuses d...

Страница 3: ...the transfer of body oils from the hands to the surface of the reflector Vent Kit F102840 1 2 3 x 2 Pipe 26GA 2 1 36 x 3 B Vent 3 1 Gas Vent Top 3 4 1 Adj Wall Thimble 5 1 Storm Collar 6 1 3 Elbow 7...

Страница 4: ...t energy downward to the space to be heated Heat Exchanger A U shaped tube through which the heated products of combustion pass Rear Movable Hanger Provides support for the heat exchanger and reflecto...

Страница 5: ...ectrical Rating 120VAC 60Hz single phase 1 amp Connection 3 pin molded plug Gas Inlet Connection Connection Male NPT Gas Inlet Pressure The minimum inlet gas supply pressure for the purpose of input a...

Страница 6: ...nting requirements for the MHT tube heater Specifies the national standards and applicable codes that apply to the gas electric and venting requirements Specifies the national standards and applicable...

Страница 7: ...above the floor Minimum required safe distances to combustibles must be maintained from vehicles parked below the heater When installed over hoists the minimum required safe distances to combustible...

Страница 8: ...as required Choose Location for Heater When selecting a suitable mounting location for the MHT tube heater it is important to consider the following 1 The heater must meet the minimum mounting height...

Страница 9: ...ontal venting sections must slope away from the heater at a rate of per foot 5 The total length of vent pipe horizontal and vertical runs combined plus the length of the exterior termination must not...

Страница 10: ...nted through the roof be sure to carefully review the roof option installa tion portion of this section Ensure that the selected mounting site will satisfy the measurement param eters vent length not...

Страница 11: ...he gaskets The tube ends extend through the flanges to help with alignment 3 Using the four long and four short nuts from the bolt kit 02876 secure the tube set to the burner box As shown in the diagr...

Страница 12: ...current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved d...

Страница 13: ...ustible wall refer to the latest edition of the National Fuel Gas Code or the authority having jurisdiction In regions of the country where prevailing winds are consistently higher than 40 mph it may...

Страница 14: ...is is to be constructed of galvanized sheet metal or other approved noncombustible corrosion resistant material as indicated by state and or local codes 2 For horizontal venting the vent lengths may b...

Страница 15: ...ength should be shortened or insulated g For vent specifications all of the following conditions must be met The maximum equivalent length of vent pipe should be carefully observed A safety switch in...

Страница 16: ...e area opening shall be provided below the heater for each 1 000 Btu hr of heater input When outside air is used the opening below the heater shall be one square inch of free area for each 4 000 Btu h...

Страница 17: ...hown below To check system pressure a plugged 1 8 NPT tapping is required upstream of the manual gas shut off valve supplied with the heater Before connecting the heater to the supply system verify th...

Страница 18: ...ns and burrs 3 Use LP resistant joint compound on all threads 4 Check the pipe and tube connections for leaks before placing heating equipment into service When checking for gas leaks use a soap and w...

Страница 19: ...will then occur 8 Periodic visual check of burner flame while unit is in operation through sight glass in bottom of unit Section 6 MAINTENANCE Pre Season Maintenance Heater area to be kept clear and f...

Страница 20: ...itch does not operate Igniter spark gap incorrect Try This Unplug heater power cord from the electrical outlet wait for a minimum of five seconds Plug heater cord back into outlet Unplug heater power...

Страница 21: ...nlet pressure requirements contact the gas company Check for 24V across valve terminals Check Shutoff On Valve IF NO Check wiring between the ignition module and the valve Repair replace wires as requ...

Страница 22: ...ters on the illustrations are keyed to the associated parts list I B A C J F H G D E ITEM PART NUMBER DESCRIPTION HST 35 HST 45 A 02808 Spark Electrode 1 1 B 02837 Ignition Wire 1 1 05795 Orifice MHT...

Страница 23: ...CHASE REF ITEM DESCRIPTION A F202850 MHT 45NG Burner Box for F208850 F202851 MHT 45LP Burner Box for F202851 B F106250 MHT45 Tube Set Long C 06014 Hanger D 06016 Hanger Clamp E 06008 9 MHT 45 Reflecto...

Страница 24: ...the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There a...