Mr. Heater HST45 Скачать руководство пользователя страница 1

01/05 Revision L1 #02853

Enerco Group, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-916-3000

Improper installation, adjustment, alteration, service or maintenance 

can cause injury or property damage. Refer to this manual. For assistance or  
additional information consult a qualified installer, service agency or the gas supplier.

WARNING:

—  WHAT TO DO IF YOU SMELL GAS
  •  Open Windows

  • 

DO NOT

 try to light any appliance.

  • 

DO NOT

 use electrical switches.

  • 

DO NOT

 use any telephone in your house. Immediately call your local gas supplier from a  

 

 

neighbor’s telephone. Follow the gas supplier’s instructions.

 

• 

Do not

 touch any electrical switch; do not use any phone in your building.

 

• 

   

 

supplier.

  • 

If you cannot reach your gas supplier, call the Fire Department.

Gas-Fired, Low-Intensity Infrared Heaters  

approved for residential Garage/Commercial Applications

FOR YOUR SAFETY: 
Do not store or use gasoline or other flammable vapors and liquids in the vicin-
ity of this or any other appliance.

WARNING: If the information in these instructions are not followed exactly, a fire or 
explosion may result causing property damage, personal injury or loss of life.

Model #

MHT 45

READ INSTRUCTIONS CAREFULLY:

 Read and follow all instructions. Place instructions in a safe place 

for future reference. Do not allow anyone who has not read these instructions to assemble, light, 
adjust or operate the heater.

OPERATING INSTRUCTIONS 

AND OWNER’S MANUAL

Содержание HST45

Страница 1: ...any electrical switch do not use any phone in your building supplier If you cannot reach your gas supplier call the Fire Department Gas Fired Low Intensity Infrared Heaters approved for residential Ga...

Страница 2: ...Echec pour se conformer aux precautions et aux in structions a fourni avec cet appareil de chauffage avoir pour resultat la mort blessure et la perte de propriete ou les dommages physiques serieuses d...

Страница 3: ...the transfer of body oils from the hands to the surface of the reflector Vent Kit F102840 1 2 3 x 2 Pipe 26GA 2 1 36 x 3 B Vent 3 1 Gas Vent Top 3 4 1 Adj Wall Thimble 5 1 Storm Collar 6 1 3 Elbow 7...

Страница 4: ...t energy downward to the space to be heated Heat Exchanger A U shaped tube through which the heated products of combustion pass Rear Movable Hanger Provides support for the heat exchanger and reflecto...

Страница 5: ...ectrical Rating 120VAC 60Hz single phase 1 amp Connection 3 pin molded plug Gas Inlet Connection Connection Male NPT Gas Inlet Pressure The minimum inlet gas supply pressure for the purpose of input a...

Страница 6: ...nting requirements for the MHT tube heater Specifies the national standards and applicable codes that apply to the gas electric and venting requirements Specifies the national standards and applicable...

Страница 7: ...above the floor Minimum required safe distances to combustibles must be maintained from vehicles parked below the heater When installed over hoists the minimum required safe distances to combustible...

Страница 8: ...as required Choose Location for Heater When selecting a suitable mounting location for the MHT tube heater it is important to consider the following 1 The heater must meet the minimum mounting height...

Страница 9: ...ontal venting sections must slope away from the heater at a rate of per foot 5 The total length of vent pipe horizontal and vertical runs combined plus the length of the exterior termination must not...

Страница 10: ...nted through the roof be sure to carefully review the roof option installa tion portion of this section Ensure that the selected mounting site will satisfy the measurement param eters vent length not...

Страница 11: ...he gaskets The tube ends extend through the flanges to help with alignment 3 Using the four long and four short nuts from the bolt kit 02876 secure the tube set to the burner box As shown in the diagr...

Страница 12: ...current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved d...

Страница 13: ...ustible wall refer to the latest edition of the National Fuel Gas Code or the authority having jurisdiction In regions of the country where prevailing winds are consistently higher than 40 mph it may...

Страница 14: ...is is to be constructed of galvanized sheet metal or other approved noncombustible corrosion resistant material as indicated by state and or local codes 2 For horizontal venting the vent lengths may b...

Страница 15: ...ength should be shortened or insulated g For vent specifications all of the following conditions must be met The maximum equivalent length of vent pipe should be carefully observed A safety switch in...

Страница 16: ...e area opening shall be provided below the heater for each 1 000 Btu hr of heater input When outside air is used the opening below the heater shall be one square inch of free area for each 4 000 Btu h...

Страница 17: ...hown below To check system pressure a plugged 1 8 NPT tapping is required upstream of the manual gas shut off valve supplied with the heater Before connecting the heater to the supply system verify th...

Страница 18: ...ns and burrs 3 Use LP resistant joint compound on all threads 4 Check the pipe and tube connections for leaks before placing heating equipment into service When checking for gas leaks use a soap and w...

Страница 19: ...will then occur 8 Periodic visual check of burner flame while unit is in operation through sight glass in bottom of unit Section 6 MAINTENANCE Pre Season Maintenance Heater area to be kept clear and f...

Страница 20: ...itch does not operate Igniter spark gap incorrect Try This Unplug heater power cord from the electrical outlet wait for a minimum of five seconds Plug heater cord back into outlet Unplug heater power...

Страница 21: ...nlet pressure requirements contact the gas company Check for 24V across valve terminals Check Shutoff On Valve IF NO Check wiring between the ignition module and the valve Repair replace wires as requ...

Страница 22: ...ters on the illustrations are keyed to the associated parts list I B A C J F H G D E ITEM PART NUMBER DESCRIPTION HST 35 HST 45 A 02808 Spark Electrode 1 1 B 02837 Ignition Wire 1 1 05795 Orifice MHT...

Страница 23: ...CHASE REF ITEM DESCRIPTION A F202850 MHT 45NG Burner Box for F208850 F202851 MHT 45LP Burner Box for F202851 B F106250 MHT45 Tube Set Long C 06014 Hanger D 06016 Hanger Clamp E 06008 9 MHT 45 Reflecto...

Страница 24: ...the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There a...

Отзывы: