DA7000SSA3 GENERATOR• OPERATION MANUAL — REV. #0 (02/13/19) — PAGE 39
STOPPING ENGINE (STARTER SWITCH FAILURE)
In the event the engine continues to run even after the
starter switch has been placed in the
STOP
position,
following the procedure on the next column to turn off the
engine.
1. Place fuel cock lever (Figure 41) in the
CLOSED
position.
2. Place engine stop lever (Figure 43) in the
STOP
position. Continue pushing stop lever until the engine
has completely stopped.
Figure 43. Engine Stop Lever
REMOVING WATER FROM THE FUEL TANK
1. After prolonged use, water and other impurities
accumulate in the bottom of the tank. Occasionally
inspect the fuel tank for water contamination.
2. If water contamination is present within the fuel tank,
remove the fuel tank drain bolt and o-ring (Figure 44),
then allow the fuel to drain into a suitable container.
NOTICE
If air enters the fuel injection system of a diesel engine,
starting becomes impossible. After running out of
fuel, or after disassembling the fuel system, bleed
the system.Reference the
Kubota Operation and
Maintenance Manual
for details.
PUSH
STOP
POSITION
ENGINE
STOP LEVER
MAINTENANCE
Figure 44. Draining Fuel Tank
3. During cold weather, the more empty volume inside
the tank, the easier it is for water to condense. This
can be reduced by keeping the tank full with diesel fue
CLEANING INSIDE THE FUEL TANK
1. If necessary, drain the fuel inside the fuel tank
completely. Using a spray washer (Figure 45) wash out
any deposits or debris that have accumulated inside
the fuel tank.
Figure 45. Fuel Tank Cleaning
2. Reinstall fuel tank drain bolt with o-ring and tighten.
7000
FUEL DRAIN BOLT
AND O-RING