DA7000SSA3 GENERATOR• OPERATION MANUAL — REV. #0 (02/13/19) — PAGE 21
30.
AC Voltmeter
— This voltmeter indicates (with a
mark) the rated 60 Hz (single-phase) output voltage.
In addition the voltmeter can also be used as a
diagnostic tool. If the voltmeter indicator (needle) is
below the rated voltage, engine problems may exist
(low/high RPM's). To prevent damage to the generator
or power tools turn the generator
OFF
and consult your
authorized Multiquip service dealer.
31.
Idle Control Switch
— The generator is provided with
an automatic idle control device for noise suppression
and reduced fuel consumption.
The automatic idle control automatically engages under
a no-load condition. With the automatic idle control
switched
ON
, the engine revolutions will automatically
drop to about 2200 rpm (low-speed operation) within
3 seconds after the load stops. When the operation is
resumed, the engine speed is automatically increased
to about 3600 rpm (high-speed operation) as soon as
the load is connected.
32.
Engine Warning Lamps
— There are four engine
warning lamps, they are defined as follows:
a.
Low Oil Pressure Alarm Lamp
— During normal
operation of the generator this lamp
will remain OFF. When the ignition
switch is placed in the RUN position
to start the engine, the lamp will be
ON. When the oil pressure rises
after start-up the lamp will go OFF.
If this lamp is ever lit (
ON
) during normal operation
of the generator, the emergency shutdown system
will stop the engine automatically.
b.
Water Temperature Alarm Lamp
— This lamp
goes ON when the cooling water
temperature rises abnormally. If
the lamp goes ON during normal
operation of the generator, the
emergency shutdown system will
stop the engine automatically.
c.
Battery Charge Alarm Lamp
— This lamp is
ON when the output voltage of
the alternator drops below a set
value. If this lamp is ON during
normal operation, the emergency
shutdown system will immediately
stop the engine.
d.
Pre-Heat Lamp
— The pre-heat lamp will be ON
during the pre-heating cycle (cold weather
conditions). When the pre-heat cycle is completed
the lamp will turn OFF and the engine can be
started.
In addition this lamp displays
engine trouble shooting faults via
flashes (blinking). See engine
trouble codes in the maintenance
section of this manual.
33.
Starter Switch
— With key inserted turn clockwise to
start engine.
34.
Hour Meter
— Indicates number of hours machine
has been in use or hours engine was run.
Figure 6. Generator Components (3 of 3)
COMPONENTS (GENERATOR)
34
31
32
S-3031
CIRCUIT BREAKER
for 120V
20A
for 120V
30A
for 120V/240V
30A
AC VOLTMETER
HOUR METER
IDLE CONTROL
OFF
ON
STOP
RUN
HEAT
START
STARTER SWITCH
QUARTZ
WHISPERWATT
7kW AC GENERATOR
ALL RECEPTACLES
G.F.C.I. PROTECTED
AC CIRCUIT BREAKER
G.F.C.I. PROTECTED
120V
240/120V
FULL POWER
SWITCH
A91110000
AUTO RESET
P
O
W
E
R
F
A
U
L
T
V
240
120
0
ON
I
O
OFF
25
30
33