54
2
Running Manual Calibrate
12. During the last step of Run Manual Cal, the printer advances the media
and attempts to detect the label length indicators and stop at the
Top-of-Form position. The Sensed Distance value will then display for
one second. The calibrate is successful when the Sensed Distance value
correctly matches that of the installed media. If “CALIBRATION FAIL/See
Manual” displays, run a manual calibrate again.
NOTE:
The amount of media sampled during manual calibration is based on
the length of a label and the transitions detected without error,
between a label and its label length indicators.
13. Press the (Pause) key until OFFLINE displays.
14. Press the
(Feed) key several times. Each time you presss
the
media advances one label length and stops.
NOTE:
After a form feed, the position of the leading edge of the next label
depends on the
type of Media Handling mode selected under the
MEDIA SETUP menu. Tear-Off Strip Media Handling positions the
label edge at the tear bar, while Continuous positions the label edge
under the printhead.
15. Once the correct values are confirmed, save them to the desired
configuration menu before powering off the printer. See “Saving A
Configuration” on page 147.