7
Discharge Unit:
The discharge unit is placed in the conveyor system at any location of desired product discharge. The discharge
unit has a pneumatic rotary actuated drop-door which allows for remotely opening and closing the discharge.
Multiple discharge units may be placed in a system when multiple discharge points are required.
The discharge unit is to be ceiling suspended or base mounted. *unit weighs app. 190 lbs (86.2 kg)
Note:
•
Air pressure to the rotary actuator should not exceed 120 PSI.
•
Air flow controllers are used to control the speed of the door actuation by controlling the air flow into and
out of the rotary actuator. Adjust the air flow so that the door does not slam closed, or swing open too
quickly.
•
The rotary actuator uses app. 6.5 in
3
[.10 liters] of air at 87 PSI [6 bars] to cycle one time (open & close).
•
For best results, a filter separator should be used on all compressed air supplies.
To aid in discharge of product and to keep the chain/discs clean of any residue, each discharge unit is equipped with
adjustable air jets. The air jets are adjusted by using the air flow controller to reduce and increase air flow to the
jets. To allow for pressure relief, all units are supplied with a low-profile breather vent. In applications where the
breather vent is not desired, the port can be plugged with any 3/8” NPT plug.
•
The air jets of each Discharge Valve use a total of 44 SCFM of air at 80 PSI [5.5 bars].