MESSTEC Power Converter GmbH
Operating Manual
TEC Controller
Document: 10100920OM
Revision: 1.1
Date: 10.10.2019
Page 62/71
10.2.7. Enable Mode
Click this button to change the enable mode between hardware and software.
That is the way, the TEC-Controller can be activated.
Hardware:
The input signal HW Enable activates the TEC-Controller.
Software:
The Start button in the main menu and the input signal
HW enable in combination, activates the TEC-Controller.
See also section
Control Signals Digital X2.
Note:
Enable mode can only be changed (Enable button is active), when
the input signal HW Enable is disabled.
Note: When enable mode is set to hardware, the Start button in the main
menu is not active.
10.2.8. Setpoint Mode
Click this button to change the setpoint mode between hardware and software.
That is the way, the desired temperature is determined and entered into the
TEC-Controller.
Hardware:
An analog voltage, which is proportional to the setpoint tempe-
rapture, is applied to the HW SETPOINT input.
Software:
The setpoint temperature is selected in the main menu.
See also section
Control Signals Analog X1
.
Note:
The HW SETPOINT input is highly configurable.
See section Configuration in Detail / HW Setpoint.
10.2.9. Colours
Click this button to open the next menu. Colours can be customized as
desired.