MESSTEC Power Converter GmbH
Operating Manual
TEC Controller
Document: 10100920OM
Revision: 1.1
Date: 10.10.2019
Page 36/71
CD-STATUS
– Output (X2-4)
Control Digital
– STATUS
Output resistance: 330 Ω
Digital TTL (5 V) output.
Default configuration: high active
STATUS = inactive:
TEC-Controller is disabled OR
sensor temperature is o/- 1 °C of the setpoint value.
STATUS = active:
TEC-Controller is enabled AND
sensor temperature is /- 1 °C of the setpoint value.
GND
– (X2-5)
Signal GND
Reference potential for CD signals.