MESSTEC Power Converter GmbH
Operating Manual
TEC Controller
Document: 10100920OM
Revision: 1.1
Date: 10.10.2019
Page 56/71
With the Start button the TEC-Controller is enabled, when enable
mode is set to software. When set to hardware, the Start button is
greyed out (see right).
With the Reset button, error states can be reset (see Error states).
Note: This is not a Reset button for the MCU.
Config. button opens the Configuration menu (see Configuration).
Note: The Config. button is only active, when the TEC-Controller is disabled.
End button quits the PC-Software.
It is possible, to show the temperature profile in a graphic chart.
With Show Graph and Hide Graph the chart is opened or closed,
respectively. Axes are scaled automatically.
On the bottom of the Graph it is possible to choose an averaging factor.
Default setting is 5.
The size of the graph window can be set by clicking on one of the corners with
the left mouse button, and holding the mouse button. Move the corner to set
desired size.