background image

TAP-125-U-W-X-Z 
(YYYYYYYY) 

Other Console Considerations 

4-3 

 

 

 

2.

 

Warning messages will pop out to warn users that the security certificate was issued by a company they 
have not chosen to trust. 

 

3.

 

Select Yes to accept the certificate issued by Moxa IW and then enter the TAP-125-U-W-X-Z 
(YYYYYYYY)’s web browser interface secured via HTTPS/SSL. (You can see the protocol in URL is https.) 
Then you can use the menu tree on the left side of the window to open the function pages to access each 
of TAP-125-U-W-X-Z (YYYYYYYY)’s functions. 

 

 

Disabling Telnet and Browser Access 

If  you  are  connecting  the  TAP-125-U-W-X-Z  (YYYYYYYY)  to  a  public  network  but  do  not  intend  to  use  its 
management  functions  over  the  network,  then  we  suggest  disabling  both  Telnet  Console  and  Web 
Configuration.  Please  run  Maintenance 

 

Console  Settings  to  disable  them,  as  shown  in  the  following 

figure. 

 

Содержание TAP-125 Series

Страница 1: ...TAP 125 u w x z yyyyyyyy User s Manual Edition 1 0 August 2019 www moxa com product 2019 Moxa Inc All rights reserved...

Страница 2: ...ges to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no respo...

Страница 3: ...ed Settings 3 15 Using Virtual LAN 3 15 Configuring Virtual LAN 3 16 DHCP Server for AP mode only 3 17 Packet Filters 3 18 SNMP Agent 3 20 Auto Warning Settings 3 22 System Log 3 23 Syslog 3 23 E mail...

Страница 4: ...tworks The TAP 125 provides a faster data rate wider range and noticeably stronger signal at the same distance compared with 802 11ac Wave 2 models The TAP 125 is compliant with EN 50155 covering oper...

Страница 5: ...ial wireless applications Package Checklist Moxa s TAP 125 U W X Z YYYYYYYY is shipped with the following items If any of these items is missing or damaged please contact your customer service represe...

Страница 6: ...fication is obtained Please check Moxa s website for the most up to date certification status Security SSID broadcast enable disable 64 bit and 128 bit WEP encryption WPA WPA2 Personal and Enterprise...

Страница 7: ...ent Relative Humidity 5 to 95 non condensing Power Requirements Input Voltage 24 to 110 VDC Power Consumption 36 W 0 327 A 110 VDC 1 5 A 24 VDC Standards and Certifications Safety UL 60950 1 EN 60950...

Страница 8: ...t an IP address from the DHCP server Blinking fast at 0 5 sec intervals IP address conflict OFF There are no error conditions STATE Green ON Software is ready Blinking Reserved OFF The TAP 125 is runn...

Страница 9: ...up your wireless network and test whether the connection is running well The Function Map discussed in the third section provides a convenient means of determining which functions you need to use The...

Страница 10: ...field to access the homepage of the web based Network Manager Before the homepage opens you will need to enter the user name and password as shown in the following figure For first time configuration...

Страница 11: ...nction Map Quick overview of the TAP 125 U W X Z YYYYYYYY s status Basic settings for administering the TAP 125 U W X Z YYYYYYYY Essential settings related to establishing a wireless network Advanced...

Страница 12: ...nfo Settings Network Settings Time Settings Wireless Settings Basic Wireless Settings WLAN Security Settings Advanced Wireless Settings Advanced Settings Using Virtual LAN Configuring Virtual LAN DHCP...

Страница 13: ...he built in monitoring and network administration functions The recommended web browser is Microsoft Internet Explorer 7 0 or 8 0 with JVM Java Virtual Machine installed Follow these steps to access t...

Страница 14: ...YYY s functions In the following paragraphs we describe each TAP 125 U W X Z YYYYYYYY management function in detail A quick overview is available in this manual in the Function Map section of Chapter...

Страница 15: ...as shown in the following figure Basic Settings The Basic Settings group includes the most commonly used settings required by administrators to maintain and control the TAP 125 U W X Z YYYYYYYY Syste...

Страница 16: ...rmation Setting Description Factory Default Max of 31 characters Provides information about whom to contact in order to resolve problems Use this space to record contact information of the person resp...

Страница 17: ...your browser s address field instead of entering the IP address The Secondary DNS server will be used if the Primary DNS server fails to connect None Time Settings The TAP 125 U W X Z YYYYYYYY has a t...

Страница 18: ...dvanced Time server 1 2 Setting Description Factory Default IP Name of Time Server IP or Domain name of the NTP time server The 2nd NTP server will be used if the 1st NTP server fails to connect Time...

Страница 19: ...F type Setting Description Factory Default 2 4 GHz B Only supports the IEEE 802 11b standard B G N Mixed G Only supports the IEEE 802 11g standard B G Mixed Supports IEEE 802 11b g standards but 802 1...

Страница 20: ...t and AP to be able to communicate with each other MOXA SSID broadcast Setting Description Factory Default Enable Disable SSID can be broadcast or not Enable Client Isolation for AP mode only Client i...

Страница 21: ...n Factory Default Netmask for allowed subnet definition The netmask of the subnet definition Hosts in this subnet can be accessed by other hosts or wireless clients in the same subnet You can also def...

Страница 22: ...pen System authentication type is used when WEP data encryption is run with authentication When WEP is enabled as a security mode the length of a key so called WEP seed can be specified as 64 128 bits...

Страница 23: ...sion of 802 11i The initial vector is transmitted encrypted and enhanced with its 48 bits twice as long as WEP The key is regularly changed so that true session is secured Even though AES encryption i...

Страница 24: ...00 seconds 6 minutes Longer time periods can be considered if the line is not very busy WPA WPA2 Enterprise By setting WPA type to Enterprise you can use EAP Extensible Authentication Protocol a frame...

Страница 25: ...etting Description Factory Default 60 to 86400 seconds 1 minute to 1 year Specifies the time period of group key renewal 3600 seconds Advanced Wireless Settings Additional wireless related parameters...

Страница 26: ...device increases the efficiency of your network by dividing the LAN into logical segments as opposed to physical segments In general VLANs are easier to manage The Virtual LAN VLAN Concept What is a V...

Страница 27: ...he AP would insert VLAN headers or tags with identifiers into the packets transmitted on the wired backbone to a network switch Finally the switch would be configured to route packets from the marketi...

Страница 28: ...Protocol is a networking protocol that allows administrators to assign temporary IP addresses to network computers by leasing an IP address to a user for a limited amount of time instead of assigning...

Страница 29: ...125 U W X Z YYYYYYYY can start assigning None Maximum number of users Setting Description Factory Default 1 999 Specifies how many IP address can be assigned continuously None Client lease time Setti...

Страница 30: ...e sole IP address 192 168 1 1 IP address 192 168 1 1 and netmask 255 255 255 0 refers to the range of IP addresses from 192 168 1 1 to 192 168 255 Remember to check the Active check box for each entit...

Страница 31: ...use a community string match for authentication which means that SNMP servers access all objects with read only or read write permissions using the community string public private default value SNMP V...

Страница 32: ...ata encryption key are the minimum requirements for authentication and encryption The following parameters can be configured on the SNMP Agent page A more detailed explanation of each parameter is giv...

Страница 33: ...only Setting Description Factory Default Disable No data encryption Disable DES DES based data encryption AES AES based data encryption Private key A data encryption key is the minimum requirement for...

Страница 34: ...ss client is associated or disassociated Config related events Event is triggered when Configuration Changed A configuration item has been changed Configuration file import via Web Console The configu...

Страница 35: ...nter the IP address of the 1st 2nd 3rd Syslog Server None Syslog port Setting Description Factory Default Port destination 1 to 65535 Enter the UDP port of the corresponding Syslog server 514 E mail E...

Страница 36: ...ed in the SMTP server None From e mail address Setting Description Factory Default Max 63 characters Enter the administrator s e mail address which will be shown in the From field of a warning e mail...

Страница 37: ...P trap receivers through the web page 1st 2nd Trap version Setting Description Factory Default V1 SNMP trap defined in SNMPv1 V1 V2 SNMP trap defined in SNMPv2 1st 2nd Trap server IP name Setting Desc...

Страница 38: ...lization information in real time to monitor the usage of the system processor Wireless Status The status for 802 11 info parameters such as Operation mode and Channel are shown on the Wireless Status...

Страница 39: ...YYYYY You can click Select all to select all the content in the list for further editing You can click Refresh to refresh the list DHCP Client List for AP mode only The DHCP Client List shows all the...

Страница 40: ...clear the log contents and the Refresh button to refresh the log Maintenance Maintenance functions provide the administrator with tools to manage the TAP 125 U W X Z YYYYYYYY and wired wireless netwo...

Страница 41: ...TAP 125 U W X Z YYYYYYYY can be enhanced with more value added functions by installing firmware upgrades The latest firmware is available at Moxa s download center Before running a firmware upgrade ma...

Страница 42: ...simply click on the MIB Export button and save it to your local drive Load Factory Default Use this function to reset the TAP 125 U W X Z YYYYYYYY and roll all settings back to the factory or customiz...

Страница 43: ...ft menu box the following screen will appear Click Save if you wish to update the configuration settings in the flash memory at this time Alternatively you may choose to run other functions and put of...

Страница 44: ...changes you will see just one Restart button on your screen You will not be able to run any of the TAP 125 U W X Z YYYYYYYY s functions while the system is rebooting Logout Logout helps users disconne...

Страница 45: ...requires using a short serial cable to connect the TAP 125 U W X Z YYYYYYYY to a PC s COM port can be used if you do not know the TAP 125 U W X Z YYYYYYYY s IP address The other consoles can be used t...

Страница 46: ...et mask to 255 255 255 0 Follow the steps below to access the console utility via Telnet or SSH client 1 From Windows Desktop run Start Run and then use Telnet to access the TAP 125 U W X Z YYYYYYYY s...

Страница 47: ...HTTPS SSL You can see the protocol in URL is https Then you can use the menu tree on the left side of the window to open the function pages to access each of TAP 125 U W X Z YYYYYYYY s functions Disab...

Страница 48: ...d information about wireless related technologies The information in this chapter can help you administer your TAP 125 U W X Z YYYYYYYY and plan your industrial wireless network better The following t...

Страница 49: ...r Maps DTIM and the Traffic Indicator Message TIM Beacon Interval indicates the frequency interval of AP DTIM Delivery Traffic Indication Map DTIM is contained in beacon frames It is used to indicate...

Страница 50: ...sed for this transmitter must be installed to provide a separation distance of at least 70 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmit...

Страница 51: ...OXA MAT WDB DA RM 2 0203 1m Omni directional 2 43dBi for 2 4GHz 3 80dBi for 5 15 5 25GHz 2 72dBi for 5 25 5 35GHz 2 26dBi for 5 47 5 725GHz 2 34dBi for 5 725 5 825GHz 12 MOXA ANT WDB ANM 0306 Omni dir...