background image

- 8 - 

 

 

ATTENTION 

This is a Class 1 laser/LED product. Do not stare into the laser 
beam. 

 

Federal Communications Commission Statement 

FCC: 

This device complies with part 15 of the FCC Rules. Operation is 

subject to the following two conditions: 

1.

 

This device may not cause harmful interference, and   

2.

 

This device must accept any interference received, including 
interference that may cause undesired operation. 

Switch Settings 

There are 4 DIP switches on the front panel of the ICF-1150. 

Setting 

Switch 1 

Switch 2 

RS-422 

ON 

OFF 

2-wire RS-485 

OFF 

ON 

4-wire RS-485 

OFF (default) 

OFF (default) 

 

Fiber Mode 

Switch 3 

Ring Mode 

ON 

Point to Point mode 

OFF (default) 

 

120Ω Terminator

 

Switch 4 

Enable 

ON 

Disable 

OFF (default) 

 

 

For Fiber Ring Users: 

If the Rx LEDs of the converter glow continuously, remove the 
fiber cable and then reconnect. The Rx LEDs should no longer 
glow continuously. 
NOTE: “Ring Mode” can only be used for half-duplex 
applications. 

 

 
The S3 DIP Switch is located inside the ICF-1150. When the ICF-1150 
is in RS-485 mode, use this DIP switch to configure RS-485 data 
direction control, data format, and baudrate. When the ICF-1150 is in 
RS-232/422 mode, the S3 DIP switch cannot affect RS-232/422 
communication. 
 

Direction Control and Data Format Setting 

You will need to open the product's casing to do the Direction Control 
and Data Format Setting. 

Содержание ICF-1150 series

Страница 1: ...P N 1802011500017 1802011500017 ICF 1150 Series Quick Installation Guide Version 8 2 October 2022 Technical Support Contact Information www moxa com support 2022 Moxa Inc All rights reserved...

Страница 2: ...is immune to adverse temperature and moisture conditions does not corrode or lose its signal and is not affected by short circuits power surges or static electricity Reverse Power Protection The Rever...

Страница 3: ...r located inside the product s casing To disable or change the resistor s strength the user must open the casing to reset the jumper Moxa offers a more user friendly solution that allows users to set...

Страница 4: ...th multi mode ICF 1150 M series Supports baudrates up to 921 6 kbps 3 way galvanic isolation for I models Wide operating temperature from 40 to 85 C for T models C1D2 ATEX and IECEx certified for hars...

Страница 5: ...5 ICF 1150 ST Top View Front View...

Страница 6: ...of the ICF 1150 when you take it out of the box If you need to reattach the DIN rail attachment plate to the ICF 1150 make sure the stiff metal spring is situated towards the top as shown in the figur...

Страница 7: ...1 2018 5 IEC 60079 0 Edition 7 IEC 60079 7 Edition 5 1Conditions of safe usage The Ethernet communication devices must be mounted in a tool accessible IP54 enclosure in accordance with IEC EN 60079 0...

Страница 8: ...OFF default Fiber Mode Switch 3 Ring Mode ON Point to Point mode OFF default 120 Terminator Switch 4 Enable ON Disable OFF default For Fiber Ring Users If the Rx LEDs of the converter glow continuous...

Страница 9: ...N 1 is interpreted as eight data bits with no parity bit and one stop bit Users need to adjust the DIP switch to set the data format to 10 bits Baudrate S3 Pin 5 S3 Pin 6 S3 Pin 7 S3 Pin 8 S3 Pin 9 5...

Страница 10: ...to Point Transmission Half or Full duplex Multi drop Transmission Half duplex fiber ring Environmental Operating Temperature 0 to 60 C 32 to 140 F 5 to 95 RH 40 to 85 C 40 to 185 F for T Model Storag...

Страница 11: ...e manufacturer then the protection provided by the equipment may be impaired 5 We suggest using the cable type 24 AWG American Wire Gauge and the corresponding pin type cable terminals 6 We suggest us...

Отзывы: