background image

- 7 - 

Pin 

RS-422 

4-wire RS-485 

2-wire RS-485 

GND 

GND 

GND 

Rx- 

Rx- 

Data - 

Rx + 

Rx + 

Data + 

Tx - 

Tx - 

– 

Tx + 

Tx + 

– 

Fiber Cable 

SC-Port Pinouts

 

SC-Port to SC-Port Cable Wiring

 

 

 

 

ST-Port Pinouts

 

ST-Port to ST-Port Cable Wiring

 

 

 

ATEX and IECEx Information 

1.

 

Certification number:   
DEMKO 10 ATEX 0917344X 
IECEx UL 13.0044X 

2.

 

Ambient range: 

Model 

Ambient Temp. Range 

Models without suffix   
“-T” 

0 to 60°C 

Models with suffix “T” 

-40 to 85°C 

 

 

3.

 

Certification string: Ex ec IIC T4 Gc 

4.

 

Standards covered: EN IEC 60079-0:2018, EN IEC 60079-7: 2015 
+A1:2018 

5.

 

IEC 60079-0, Edition 7, IEC 60079-7, Edition 5.1Conditions of safe 
usage: 

 

The Ethernet communication devices must be mounted in a 
tool-accessible IP54 enclosure in accordance with IEC/EN 
60079-0 and used in an area of not more than pollution 
degree 2 as defined by IEC/EN 60664-1. 

 

Provisions shall be made to prevent that transient 
disturbances should exceed the rated voltage by over 140%. 

6.

 

The Terminal blocks (J1, J2) are suitable for 14 to 28 AWG   
(3.31-0.08 mm

2

), with torque = 1.7 lb-in. The cross-sectional area 

of the PE conductor is Sp=3.31 mm

2

. The conductor used for 

grounding is 12 AWG minimum. 

7.

 

Conductors suitable for use in an ambient temperature of 91°C 
must be used for the power supply terminal. 

Содержание ICF-1150 series

Страница 1: ...P N 1802011500017 1802011500017 ICF 1150 Series Quick Installation Guide Version 8 2 October 2022 Technical Support Contact Information www moxa com support 2022 Moxa Inc All rights reserved...

Страница 2: ...is immune to adverse temperature and moisture conditions does not corrode or lose its signal and is not affected by short circuits power surges or static electricity Reverse Power Protection The Rever...

Страница 3: ...r located inside the product s casing To disable or change the resistor s strength the user must open the casing to reset the jumper Moxa offers a more user friendly solution that allows users to set...

Страница 4: ...th multi mode ICF 1150 M series Supports baudrates up to 921 6 kbps 3 way galvanic isolation for I models Wide operating temperature from 40 to 85 C for T models C1D2 ATEX and IECEx certified for hars...

Страница 5: ...5 ICF 1150 ST Top View Front View...

Страница 6: ...of the ICF 1150 when you take it out of the box If you need to reattach the DIN rail attachment plate to the ICF 1150 make sure the stiff metal spring is situated towards the top as shown in the figur...

Страница 7: ...1 2018 5 IEC 60079 0 Edition 7 IEC 60079 7 Edition 5 1Conditions of safe usage The Ethernet communication devices must be mounted in a tool accessible IP54 enclosure in accordance with IEC EN 60079 0...

Страница 8: ...OFF default Fiber Mode Switch 3 Ring Mode ON Point to Point mode OFF default 120 Terminator Switch 4 Enable ON Disable OFF default For Fiber Ring Users If the Rx LEDs of the converter glow continuous...

Страница 9: ...N 1 is interpreted as eight data bits with no parity bit and one stop bit Users need to adjust the DIP switch to set the data format to 10 bits Baudrate S3 Pin 5 S3 Pin 6 S3 Pin 7 S3 Pin 8 S3 Pin 9 5...

Страница 10: ...to Point Transmission Half or Full duplex Multi drop Transmission Half duplex fiber ring Environmental Operating Temperature 0 to 60 C 32 to 140 F 5 to 95 RH 40 to 85 C 40 to 185 F for T Model Storag...

Страница 11: ...e manufacturer then the protection provided by the equipment may be impaired 5 We suggest using the cable type 24 AWG American Wire Gauge and the corresponding pin type cable terminals 6 We suggest us...

Отзывы: