background image

 

 8 

Mounting Dimensions (unit = mm) 

EDS-P510

PoE

Side View

Front View

DIN-Rail Kit

Rear View

Mounting Kit

30

13.9

15

51.3

80.2

13.9

18.2

30.5

10

13.9

7.75

7.75

10

5

6

6

3.5

7.5

7.5

55

105

135

35

24.3

39.37

46.77

24.56

57.05

66.8

27.2

48.3

135

9

 

DIN-Rail Mounting 

The aluminum DIN-Rail attachment plate should already be fixed to the back 
panel of the EDS-P510 when you take it out of the box. If you need to 
reattach the DIN-Rail attachment plate to the EDS-P510, make sure the stiff 
metal spring is situated towards the top, as shown by the following figures. 

STEP 1

Insert the top of the 

DIN-Rail into the slot just below the 
stiff metal spring. 

STEP 2

The DIN-Rail attachment 

unit will snap into place as shown in 
the following illustration. 

metal
spring

DIN-Rail

metal
spring

DIN-Rail

To remove the EDS-P510 from the DIN-Rail, simply reverse Steps 1 and 2 
above.

 

Содержание EtherDevice EDS-P510 Series

Страница 1: ...Moxa EtherDevice Switch EDS P510 Series Hardware Installation Guide First Edition November 2008 2008 Moxa Inc All rights reserved Reproduction without permission is prohibited P N 1802005101010 ...

Страница 2: ...plays the role of PD and splits the data signal and power signal that are transmitted from the PSE The SPL 24 plays a dual role of providing power to industrial devices and enabling Ethernet connections The EDS P510 and SPL 24 can operate from 0 to 60 C or 40 to 75 C for T model and are designed to withstand a high degree of vibration and shock The rugged hardware design makes the EDS P510 Series ...

Страница 3: ...type BiDi SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission TX 1310 nm RX 1550 nm standard operating temperature 0 to 60 C y SFP 1G10BLC WDM type BiDi SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission TX 1550 nm RX 1310 nm standard operating temperature 0 to 60 C y SFP 1G20ALC WDM type BiDi SFP module with 1 1000BaseSFP port with LC connector for...

Страница 4: ... 1550 nm wide operating temperature 40 to 75 C y SFP 1G40BLC T WDM type BiDi SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission TX 1550 nm RX 1310 nm wide operating temperature 40 to 75 C y ABC 01 Automatic Backup Configurator via RS 232 Console Port 0 to 60 C y DR 75 48 DIN Rail Power Supply 48 VDC 75W 1 6A with 85 to 264 VAC input y DR 120 48 DIN Rail Power Supply 48 VDC...

Страница 5: ...ries Technology Standards IEEE 802 3af for Power over Ethernet IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X and 100Base FX IEEE 802 3ab for 1000Base X IEEE 802 3z for 1000BaseSX LX LHX ZX IEEE 802 3x for Flow Control IEEE 802 1D for Spanning Tree Protocol IEEE 802 1w for Rapid STP IEEE 802 1Q for VLAN Tagging IEEE 802 1p for Class of Service IEEE 802 1X for Authentication IEEE 802 3ad for Por...

Страница 6: ...50 mA Max Overload Protection 400 mA Power Input Voltage 48 VDC 46 to 50 VDC redundant dual inputs Connection Two removable 6 pin terminal blocks Overload Current Protection Present Reverse Polarity Protection Present Physical Characteristics Casing IP30 protection metal case Dimensions W H D 80 2 135 105 mm 3 16 5 31 4 13 in Weight 1170g Installation DIN Rail Wall Mounting Kit optional kit Enviro...

Страница 7: ...CISPR EN55022 class A EMS EN61000 4 2 ESD Level 3 EN61000 4 3 RS Level 3 EN61000 4 4 EFT Level 2 EN61000 4 5 Surge Level 3 EN61000 4 6 CS Level 3 EN61000 4 8 EN61000 4 11 Shock IEC60068 2 27 Freefall IEC60068 2 32 Vibration IEC60068 2 6 WARRANTY 5 years ...

Страница 8: ... 2 G1 to G3 Combo 10 100 1000BaseT X or 100 1000BaseSFP slot Gigabit port 3 PWR1 LED for power input 1 4 PWR2 LED for power input 2 5 Fault LED 6 Turbo Ring Logo 7 MASTER LED 8 COUPLER LED 9 G1 G2 G3 LED for 10 100 1000Mbps speed 10 Port 1 to Port 7 LED for 10 100Mbps speed 11 PoE port LED Port 1 to Port 4 12 Model name Top Panel 1 Ground screw 2 RS 232 console port 3 Heat dissipation orifices 4 D...

Страница 9: ...e back panel of the EDS P510 when you take it out of the box If you need to reattach the DIN Rail attachment plate to the EDS P510 make sure the stiff metal spring is situated towards the top as shown by the following figures STEP 1 Insert the top of the DIN Rail into the slot just below the stiff metal spring STEP 2 The DIN Rail attachment unit will snap into place as shown in the following illus...

Страница 10: ...e about 2 mm to allow room for sliding the wall mount panel between the wall and the screws STEP 3 Once the screws are fixed to the wall insert the four screw heads through the wide parts of the keyhole shaped apertures and then slide the EDS P510 downwards as indicated in the figure at the right Tighten the four screws for more stability PWR1 PWR2 FAULT 7 6 5 4 3 2 1 G1 G2 G1 G3 G2 G3 EDS P510 MA...

Страница 11: ... characteristics should be routed separately y You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together y You should separate input wiring from output wiring y We advise that you label the wiring to all devices in the system Grounding the Moxa ED...

Страница 12: ...o keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connector STEP 3 Insert the plastic terminal block connector prongs into the terminal block receptor which is located on the EDS P510 s top panel Wiring the Digital Inputs The EDS P510 has two sets of digital inputs DI 1 and DI 2 Each DI consists of two cont...

Страница 13: ...re detail information about the settings and usage of Turbo Ring and Turbo Ring V2 EDS P510 Series DIP Switches 2 1 MASTER COUPLER TURBO RING 4 3 The default setting for each DIP Switch is OFF The following table explains the effect of setting the DIP Switch to the ON position Turbo Ring DIP Switch Settings DIP 1 DIP 2 DIP 3 DIP 4 ON Enables this EDS as the Ring Master ON Enables the default Ring ...

Страница 14: ...R1 AMBER Off Power is not being supplied to power input P1 On Power is being supplied to power input P2 PWR2 AMBER Off Power is not being supplied to power input P2 On When a user configured event is triggered FAULT RED Off When a user configured event is not triggered On When the EDS P510 is the Master of this Turbo Ring MASTER GREEN Blinking When the EDS P510 is Ring Master of this Turbo Ring an...

Страница 15: ...g or damaged please contact your customer service representative for assistance y Moxa PoE Splitter SPL 24 y Hardware Installation Guide y Moxa Product Warranty Statement Features of SPL 24 High Performance Network Switching Technology y IEEE802 3af compliance y Power data split from PoE lines using either spare pairs or data pairs y Support for up to 12 95W at 24 VDC y Support for up to 15 4 watt...

Страница 16: ...H D Weight 95g Installation DIN Rail Wall Mounting Environmental Operating Temperature 0 to 60 C 32 to 140 F 40 to 75 C 40 to 167 F for T models Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals Safety Pending UL60950 UL 508 CSA C22 2 No 60950 EN60950 pending Hazardous Location UL cUL Class I Division 2 Groups A B C and D pending ATEX ...

Страница 17: ...N P 1 Heat dissipation orifices 2 Terminal block for power input and grounding 3 Moxa Logo 4 PoE power LED 5 DATA OUT port 6 PoE IN port 7 DIN Rail Mounting Dimensions unit mm 24 87 Front View Side View Rear View Top View 86 5 74 15 32 0 0 1 0 0 1 10 5 2 6 7 4 7 24 87 24 VDC OUTPUT V DATA OUT PoE IN P ...

Страница 18: ...ace as shown below DIN Rail DIN Rail DIN Rail To remove the SPL 24 from the DIN Rail insert a flat blade screw driver horizontally into the DIN Rail kit under the SPL 24 and then pull it upwards and release SPL 24 towards you away from the DIN Rail Grounding the SPL 24 Top View Front View Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the rig...

Страница 19: ...mall flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connector STEP 3 Insert the plastic terminal block connector prongs into the terminal block receptor which is located on SPL 24 s top panel Technical Support Contact Information www moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office T...

Отзывы: