24/29
NT 1004-H00 10 16 SLS24 i - SLS36 i e
10.1 Discharge port
• Unscrew the 8 nuts
106
and remove the 8 tierods
107
.
• Turn the front cover
401
so as to position the outlet port
in the desired position.
• Replace the 8 tierods
107
and tighten the nuts
106
.
• Make sure that the seal
205
is secured in its housing.
Secure it with a grease that is compatible with the
transferred product if necessary.
10.2 Suction port
• Dismantle the main body
101B
including the suction port
as indicated in the corresponding §.
• Re-mount the main body
101B
in the desired position by
fitting the indexing pins in the housings provided in the
bearing
596
and the flange
104
.
• Make sure that the seal
113
is secured in its housing.
Secure it with a grease that is compatible with the
transferred product if necessary.
WARNING
BE CAREFUL WITH THE WEIGHT OF THE
PARTS WHEN THEY ARE BEING REMOVED.
The weight ot the parts
can be dangerous and
may provoke bodily
injuries or material
damages.
10. CHANGING THE ORIENTATION OF THE PORTS