13/29
NT 1004-H00 10 16 SLS24 i - SLS36 i e
3.1 Noise level
The sound level of a pump is greatly influenced by its
conditions of use. Cavitation and pumping products with
high gas contents generally increases the sound level.
Under the following pumping conditions :
• excluding cavitation
• discharge pressure :
• SLS24 : . . . . 9 bar (130,5 psi)
• SLS36 : . . . . 6 bar (87 psi)
• speed of rotation 450 rpm
• product viscosity of 1 cSt
The sound level reached for the SLS24 / SLS36 pump in
good conditions without the drive is less than 83 dB(A).
3.2 Commissioning
Make sure that the circuit valves are open before star-
ting the pump.
To avoid any risk of polluting the product to be pumped,
rinse the whole installation before starting-up so as to
eliminate any contaminants that may remain in the
piping, tanks etc. at the time of installation.
3.3 Dry running
The SLS series pump is self priming and is capable of
emptying the pipes. To do this, it can run dry for a maxi-
mum duration of 5 minutes.
3.4 Pump stop
So as not to damage the pump, make sure that the
pump is completely stopped before closing the valves.
3.5 Scrapping
The pump must be scrapped in compliance with the
regulations in force.
During this operation, particular care must be paid to the
drainage stages of the pump (pumped product) and of
its transmission (lubricant).
For any pure water pumping during process or
cleaning operations, consult Mouvex imperatively.
3. UTILISATION