Pu202_02d_oi_e.doc / Apr-16 

 

Page 3 / 10 

1.

 

Safety Instructions and Responsibility 

1.1

 

General Safety Instructions 

This operation manual is a significant component of the unit and includes important rules and 
hints about the installation, function and usage. Non-observance can result in damage and/or 
impairment of the functions to the unit or the machine or even in injury to persons using the 
equipment!  

 

Please read the following instructions carefully before operating the device and observe all 
safety and warning instructions! Keep the manual for later use.  

 

A pertinent qualification of the respective staff is a fundamental requirement in order to use 
these manual. The unit must be installed, connected and put into operation by a qualified 
electrician. 

 

Liability exclusion: The manufacturer is not liable for personal injury and/or damage to property 
and for consequential damage, due to incorrect handling, installation and operation. Further 
claims, due to errors in the operation manual as well as misinterpretations are excluded from 
liability. 

 

In addition the manufacturer reserve the right to modify the hardware, software or operation 
manual at any time and without prior notice. Therefore, there might be minor differences 
between the unit and the descriptions in operation manual. 

 

The raiser respectively positioner is exclusively responsible for the safety of the system and 
equipment where the unit will be integrated.  

 

During installation or maintenance all general and also all country- and application-specific 
safety rules and standards must be observed.  

 

If the device is used in processes, where a failure or faulty operation could damage the system 
or injure persons, appropriate precautions to avoid such consequences must be taken. 
 

1.2

 

Use according to the intended purpose 

The unit is intended exclusively for use in industrial machines, constructions and systems. Non-
conforming usage does not correspond to the provisions and lies within the sole responsibility 
of the user. The manufacturer is not liable for damages which has arisen through unsuitable 
and improper use.  

 

Please note that device may only be installed in proper form and used in a technically perfect 
condition - in accordance to the Technical Specifications (see chapter 

8

). The device is not 

suitable for operation in explosion-proof areas or areas which are excluded by the EN 61010-1 
standard. 
 

Содержание PU202

Страница 1: ...al separation Product features Converts HTL signals from 10 up to 30 V A B Z into the corresponding TTL RS422 format the inverted channels included Further different standards of direction signals can...

Страница 2: ...eproduction modification usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH Table of Contents 1 Safety Instructi...

Страница 3: ...e right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual Th...

Страница 4: ...sections for wiring are described in the Technical Specifications see chapter 8 Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw term...

Страница 5: ...ontrollers Some measuring systems or PLC positioning cards generate pulses on one line whilst another line provides static information of the direction of rotation Other systems use two separate lines...

Страница 6: ...unit is designed as a PCB with a plastic housing for a simple snapping ontotop hat rails according to the EN 60715 norm The impulse input are available on a 9 pin SUB D connector female For power supp...

Страница 7: ...inal Also Pin 4 of the input connector is on same potential as the 24V screw terminal This enables the user to externally supply an encoder system via the Sub D connector without necessity to split th...

Страница 8: ...converted to TTL level but not be affected by the mode setting ON 6 1 Quadrature Input A B 2 x 90 1 2 3 4 5 6 7 8 ON OFF S2 6 2 Impulses on line A only static direction select on line B Low forward Hi...

Страница 9: ...90 only at a certain input frequency and will become smaller with lower input frequencies This in general this is not a restriction for proper detection of the direction because most of the controller...

Страница 10: ...Frequency Connections HTL 10 30 V PNP Ri 10 kOhm A B Z max 200 kHz male SUB D connector 9 pin Incremental output Levels Channels Output current Signal delay Connections 5 V TTL RS422 A A B B Z Z max...

Отзывы: