Pu202_02d_oi_e.doc / Apr-16
Page 7 / 10
4.
Power Supply
The unit does not possess its own power supply unit. It must be supplied by an external source
with +5 VDC +/-10% (approx. 50mA), which can either be connected to the 9-position output
connector or the screw terminals marked “GND” and “5V” (see connection diagram below).
Pin 4 of the output connector is internally connected to the +5V screw terminal.
Also, Pin 4 of the input connector is on same potential as the +24V screw terminal.
This enables the user to externally supply an encoder system via the Sub- D- connector without
necessity to split the 9- wire cable.
The +24V*) screw terminal serves as encoder supply only and does not affect the operation of
the unit.
The 5 VDC unit supply is protected against wrong polarity by a diode and a fuse.
5.
Connection diagram
GN
D
GN
D
+2
4V
)
*
GN
D
GN
D
+5V
4
+24V*)
3
IN A
1
IN B
7
IN Z
5
GND
1
9
7
6
5
GND
2
3
A
4
+5V
/A
B
/B
Z
/Z
Fuse
0,315mt
+5V
GND
(Sub - D- 9 male)
(Su b- D- 9 female)
Screen
Screen
Power Supply