background image

Pu202_02d_oi_e.doc / Apr-16 

 

Page 2 / 10 

 

Version: 

Description: 

PU20202c/Sept.07/hk 

Remake as brochure with A5 format 

Pu202_02d/Okt-15/ag 

- Safety Instructions and Technical Specification updated 
- Design updated and Legal notices supplemented 
- Pulse diagram correction (10 … 30 V instead of 12-30V) 
- Pulse diagram moved from page 1 into a new chapter (2.1) 

 

Legal notices: 

All contents included in this manual are protected by the terms of use and copyrights of motrona GmbH. Any reproduction, 
modification, usage or publication in other electronic and printed media as well as in the internet requires prior written 
authorization by motrona GmbH.

 

 

Table of Contents 

 

1.

 

Safety Instructions and Responsibility ......................................................... 3

 

1.1

 

General Safety Instructions ................................................................................... 3

 

1.2

 

Use according to the intended purpose ................................................................ 3

 

1.3

 

Installation ............................................................................................................. 4

 

1.4

 

Cleaning, Maintenance and Service Notes ........................................................... 4

 

2.

 

Introduction ................................................................................................. 5

 

3.

 

Construction, Dimensions ............................................................................ 6

 

4.

 

Power Supply ............................................................................................... 7

 

5.

 

Connections ................................................................................................. 7

 

6.

 

Modes of Operation ..................................................................................... 8

 

6.1.

 

Quadrature Input A/B ............................................................................................ 8

 

6.2.

 

Impulses on line A only, static direction select on line B ..................................... 8

 

6.3.

 

Separate impulse lines for forward and reverse ................................................... 8

 

7.

 

Output Signal ............................................................................................... 9

 

8.

 

Technical Specifications ............................................................................ 10

 

 

Содержание PU202

Страница 1: ...al separation Product features Converts HTL signals from 10 up to 30 V A B Z into the corresponding TTL RS422 format the inverted channels included Further different standards of direction signals can...

Страница 2: ...eproduction modification usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH Table of Contents 1 Safety Instructi...

Страница 3: ...e right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual Th...

Страница 4: ...sections for wiring are described in the Technical Specifications see chapter 8 Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw term...

Страница 5: ...ontrollers Some measuring systems or PLC positioning cards generate pulses on one line whilst another line provides static information of the direction of rotation Other systems use two separate lines...

Страница 6: ...unit is designed as a PCB with a plastic housing for a simple snapping ontotop hat rails according to the EN 60715 norm The impulse input are available on a 9 pin SUB D connector female For power supp...

Страница 7: ...inal Also Pin 4 of the input connector is on same potential as the 24V screw terminal This enables the user to externally supply an encoder system via the Sub D connector without necessity to split th...

Страница 8: ...converted to TTL level but not be affected by the mode setting ON 6 1 Quadrature Input A B 2 x 90 1 2 3 4 5 6 7 8 ON OFF S2 6 2 Impulses on line A only static direction select on line B Low forward Hi...

Страница 9: ...90 only at a certain input frequency and will become smaller with lower input frequencies This in general this is not a restriction for proper detection of the direction because most of the controller...

Страница 10: ...Frequency Connections HTL 10 30 V PNP Ri 10 kOhm A B Z max 200 kHz male SUB D connector 9 pin Incremental output Levels Channels Output current Signal delay Connections 5 V TTL RS422 A A B B Z Z max...

Отзывы: