4.2.
General Parameters
This register card holds the essential variable settings of general nature
Length1
Preset of the desired cutting length 1 scaled in length units according to
user definition (active with input “Length Selection” = LOW)
Length2
Preset of the desired cutting length 2 scaled in length units according to
user definition (active with input “Length Selection” = HIGH)
Max Frequency
Expected maximum frequency of the master encoder (Hz). Used for pre-
scaling of the analogue output.
Virtual Master
Speed
Preset speed of the virtual master axis (Hz)
Gap Overspeed
Temporary overspeed after the cut to create a gap
(Added supplementary speed = Actual line speed x register setting)
Min. Length
Lower limit for length preset values (Length units)
Max. Length
Upper limit for length preset values (Length units)