CT70104B_e.doc / Nov-15
Page 11 / 29
Ser Bus
Command 16
…
Command 28
Not in use
Ser Bus Store to EEPROM
Stores all actual parameters and variables to the EEPROM
Ser Bus Adjust Program
Starts the Adjust program for testing and commissioning
(Will be set automatically by PC operator software when you
select “Adjust…” in menu “Tools”)
Ser Bus Test Program
Starts the Test program for testing and commissioning
(Will be set automatically by PC operator software when you
select “Test…” in menu “Tools”)
4.1.2.
Outputs
Outputs which are in use for the current application are marked with a text, and unused outputs
are marked with “output …” only.
The indicator box shines red when the corresponding output is HIGH, otherwise the box
remains white. Outputs on the screen appear in the sequence of their mechanical layout on the
connector panel
Meaning and function of the output signals:
Out1
Ready
Indicates that the unit is ready to work after power-up,
initialisation and self-test. This output, however, is not a
guarantee for trouble-free operation of all functions.
Out2
Speed too high
Goes HIGH when the analogue speed output command
exceeds the preset maximum output value
Out3
12 h position
Generates a pulse with adjustable duration every time the
shear position passes “12 o’clock” position (opposite of the
cutting position)
Out4
Homing Done
Set to on when the homing cycle is finished. Reset to off
when the home position is no more valid and a new homing
cycle should be executed (after Reset, Jog, power down etc.).
Out5
Automatic
Operation
Set to on during automatic cutting operation when input
“Start” is on. When input “Start” is reset to off, this output is
set to off not before the actual cut is finished and the cutting
roll is at standstill.
Out6
X7 – Pin6
Not in use
Out7
X7 – Pin7
Not in use
Out8
Error
An error has occured.