ZIM12-00505 Rev. 1
TransTech IV Service Manual
10
MACHINE SETUP
AUTO-PRIME (FIRST USE ONLY)
1. Check the output/return hoses, battery connections, and all external components
for damage.
2. Fill the CLEAN FLUID tank with approximately 4 quarts (3.78 liters) of new ATF.
3. Connect two compatible adapters to each other, secure tightly. Attach the
CLEAN FLUID & INLINE RETURN hoses together using the connected adapters
4. Place the waste hose into the clean tank fill neck with the ball valve open.
5. Attach the units’ red (+) battery clip to vehicle’s positive battery terminal; connect
the black (-) battery clip to a solid ground point as far from the battery as
possible.
6. Check to ensure the unit is in Inline mode (Inline LED is on). Press and hold the
START button for 5 seconds until the unit sounds the alarm. The FILL and
DRAIN LEDs will flash. Press and hold the START button again for 5 seconds
until the unit sounds the alarm. The DRAIN, FILL and COMPLETE LEDs will
cycle in a clockwise
direction while the unit is
performing the Auto-
Prime procedure. The
unit will pump fluid from
the clean tank to the
waste tank.
The unit will
then set the waste tank
zero level by pumping
fluid from the waste tank
into the clean tank.
When complete, the unit
will automatically reset.
Both tanks should have
fluid approximately at the
zero mark on the front of
the cabinet.
7. Return the hoses to their
original location.
8. The initial setup is
complete.