V.3229 / V.3229L
<C#>-9
6
Status Registers
Lost Carrier Detect
Time
S10=0-255
S10 contains the amount of time (0-255) in 0.1 sec-
ond increments carrier must be absent to be recog-
nized as a loss of carrier. The default value is 14 (1.4
seconds).
DTMF Tone
Duration
S11
S11 determines the length of DTMF tones. The
period of silence is equal to the duration of the tone.
The value of this register must be entered in multiples
of 10. Default value is 80 (80 ms).
Escape Sequence
Pause
S12=0-255
Using the escape sequence to return to command
mode from data mode requires two pauses, one be-
fore and one after the escape characters.
The pauses prevent the modem from responding to a
character sequence which might contain the escape
sequence as part of its normal data transmission.
S12 contains the pause interval in 0.02 second incre-
ments. The factory setting is 50, equivalent to 1
second (50 x 0.02 sec). When S12 is 0 then timing
is not a factor.
The timing between the 3 escape characters must be
less than the pause interval or the escape sequence
will not be detected. The data rate also affects the
timing and must be taken into account when chang-
ing the pause interval.
To disable the escape command, set S2 to a value
Содержание V3229 - 14.4 Kbps Modem
Страница 14: ... C Introduction V 3229 V 3229L C 7 Reference Installation ...
Страница 17: ... C Introduction C 10 V 3229 V 3229L Reference Installation ...
Страница 18: ... C Introduction V 3229 V 3229L C 11 Reference Installation ...
Страница 20: ... C 2 V 3229 V 3229L 3 Option Selection The strap diagrams on the following pages indicate the factory settings ...
Страница 37: ...V 3229 V 3229L C 19 3 Option Selection ...
Страница 53: ... C 16 V 3229 V 3229L Reference Operation SECURE 14400 xxx ...
Страница 61: ... C 24 V 3229 V 3229L Reference Operation ...
Страница 62: ...V 3229 V 3229L C 25 Reference Operation V 32 Cleardown ...
Страница 64: ...V 3229 V 3229L C 27 Reference Operation ...
Страница 126: ... C 62 V 3229 V 3229L 5 Asynchronous Operating Commands ...
Страница 135: ...V 3229 V 3229L C 71 5 Asynchronous Operating Commands ...
Страница 136: ... C 72 V 3229 V 3229L 5 Asynchronous Operating Commands ...
Страница 149: ...V 3229 V 3229L C 13 6 Status Registers value is 0 S19 20 ...
Страница 156: ... C 20 V 3229 V 3229L 6 Status Registers default ...
Страница 159: ...V 3229 V 3229L C 23 6 Status Registers S40 50 ...
Страница 171: ...V 3229 V 3229L C 35 6 Status Registers default ...
Страница 214: ... C 2 V 3229 V 3229L 9 Maintenance ...
Страница 221: ...V 3229 V 3229L C C Reference Interfaces ...
Страница 222: ... C D V 3229 V 3229L Reference Phone Jack Descriptions ...
Страница 259: ... C Z V 3229 V 3229L Reference Command Index and Defaults SPEAKER OPTIONS Volume medium Speaker off ...
Страница 266: ...V 3229 V 3229L C AG Reference Command Index and Defaults Indicates variation from factory option set 1 ...