V.3229 / V.3229L
<C#>-61
5
Asynchronous Operating Commands
*default
XON/XOFF Pass
Through
\X
This option is active when flow control of the modem
by the DTE has been selected for XON/XOFF and
the connect mode is reliable or normal. It enables or
disables the sending of local flow control characters
(XON/XOFF) to the remote modem as well as being
acted on in the local modem. In reliable mode the
modem treats incoming XON/XOFF characters from
the remote modem as data characters. In normal
mode the modem will look at the \G command and
act accordingly.
Caution:
With
\X1
in effect local flow control
characters will be sent to the remote system. These
characters may turn on the data flow from the remote
system before the modem is ready to receive more
data, possibly resulting in data loss.
Table 53:
\Q
Disable DTE flow control
\Q1
Enable DTE XON/XOFF flow control*
\Q2
Enable CTS flow control to the DTE
\Q3
Enable bilateral CTS/RTS flow control
\Q4
Disable DCE flow control
\Q5
Enable DCE XON/XOFF flow control*
\Q6
Enable CTS flow control to the DTE
\Q7
Enable CTS flow control to the DTE
Содержание V3229 - 14.4 Kbps Modem
Страница 14: ... C Introduction V 3229 V 3229L C 7 Reference Installation ...
Страница 17: ... C Introduction C 10 V 3229 V 3229L Reference Installation ...
Страница 18: ... C Introduction V 3229 V 3229L C 11 Reference Installation ...
Страница 20: ... C 2 V 3229 V 3229L 3 Option Selection The strap diagrams on the following pages indicate the factory settings ...
Страница 37: ...V 3229 V 3229L C 19 3 Option Selection ...
Страница 53: ... C 16 V 3229 V 3229L Reference Operation SECURE 14400 xxx ...
Страница 61: ... C 24 V 3229 V 3229L Reference Operation ...
Страница 62: ...V 3229 V 3229L C 25 Reference Operation V 32 Cleardown ...
Страница 64: ...V 3229 V 3229L C 27 Reference Operation ...
Страница 126: ... C 62 V 3229 V 3229L 5 Asynchronous Operating Commands ...
Страница 135: ...V 3229 V 3229L C 71 5 Asynchronous Operating Commands ...
Страница 136: ... C 72 V 3229 V 3229L 5 Asynchronous Operating Commands ...
Страница 149: ...V 3229 V 3229L C 13 6 Status Registers value is 0 S19 20 ...
Страница 156: ... C 20 V 3229 V 3229L 6 Status Registers default ...
Страница 159: ...V 3229 V 3229L C 23 6 Status Registers S40 50 ...
Страница 171: ...V 3229 V 3229L C 35 6 Status Registers default ...
Страница 214: ... C 2 V 3229 V 3229L 9 Maintenance ...
Страница 221: ...V 3229 V 3229L C C Reference Interfaces ...
Страница 222: ... C D V 3229 V 3229L Reference Phone Jack Descriptions ...
Страница 259: ... C Z V 3229 V 3229L Reference Command Index and Defaults SPEAKER OPTIONS Volume medium Speaker off ...
Страница 266: ...V 3229 V 3229L C AG Reference Command Index and Defaults Indicates variation from factory option set 1 ...