Programming Model
http://www.motorola.com/computer/literature
3-19
3
Tick Timer 1 Counter
The Tick Timer 1 Counter is a 32-bit read/write register located at address
$FFF42008. When enabled, it increments every microsecond. Software
may read or write the counter at any time.
Tick Timer 2 Compare Register
The Tick Timer 2 Compare Register is a 32-bit register located at
$FFF4200C. The count value of Tick Timer 2 is compared to this register.
When they are equal, an interrupt is sent to the Local Bus interrupter and
the overflow counter is incremented. If the clear-on-compare mode is
enabled, the counter is also cleared. For periodic interrupts, the following
equation should be used to determine the compare register value for a
specific period.
compare register value = T (
µ
s)
When programming the tick timer for periodic interrupts, the counter
should be cleared to zero by software and then enabled. If the counter does
not initially start at zero, the time to the first interrupt may be longer or
shorter than expected. The rollover time for the counter is 71.6 minutes.
ADR/SIZ
$FFF42008 (32 bits)
BIT
31
. . .
0
NAME
Tick Timer 1 Counter
OPER
R/W
RESET
X
ADR/SIZ
$FFF4200C (32 bits)
BIT
31
. . .
0
NAME
Tick Timer 2 Compare Register
OPER
R/W
RESET
0 P
Содержание MVME1X7P
Страница 1: ...MVME1X7P Single Board Computer Programmer s Reference Guide V1X7PA PG1 Edition of October 2000 ...
Страница 16: ...xvi ...
Страница 18: ...xviii ...
Страница 20: ...xx ...
Страница 26: ...xxvi ...
Страница 90: ...1 64 Computer Group Literature Center Web Site Programming Issues 1 ...
Страница 248: ...3 50 Computer Group Literature Center Web Site PCCchip2 3 ...
Страница 286: ...4 38 Computer Group Literature Center Web Site MCECC Functions 4 ...
Страница 288: ...A 2 Computer Group Literature Center Web Site Summary of Changes A ...
Страница 316: ...Index IN 14 Computer Group Literature Center Web Site I N D E X ...