Site planning
Chapter 2 Planning considerations
phn-2182_002v000
2-6
May 2011
The lateral force produced by a single PTP 250 ODU (integrated or connectorized
model) at different wind speeds is shown in
Table 2-2
.
Table 2-2
Lateral force – metric
Type of ODU
Largest
surface area
(square meters)
Lateral force (Kg) at wind speed
(meters per second)
30
40
50
60
70
Integrated
0.130
12 22 34 49 66
Connectorized
0.093
9 16 24 35 48
Calculation of lateral force (US)
The magnitude of the lateral force can be estimated from:
Force (in pounds) = 0.0042Av
2
Where:
Is:
A surface
area
in square feet
v
wind speed in miles per hour
The lateral force produced by a single PTP 250 ODU (integrated or connectorized
model) at different wind speeds is shown in
Table 2-3
.
Table 2-3
Lateral force – US
Type of ODU
Largest
surface area
(square feet)
Lateral force (lb) at wind speed
(miles per hour)
80
100
120
140
150
Integrated
1.36
36.6
57.1
82.3
146.2 228.5
Connectorized
1.00
26.9
42
60.5
107.5 168.0
NOTE
When the connectorized ODU is used with external antennas, the figures
from the antenna manufacturer for lateral force should be included to
calculate the total loading on the mounting structure.
Содержание Motorola PTP 250
Страница 20: ...List of Tables phn 2182_002v000 xiv May 2011 ...
Страница 30: ......
Страница 80: ...Data network planning Chapter 2 Planning considerations phn 2182_002v000 2 22 May 2011 ...
Страница 126: ...Notifications Chapter 4 Reference information phn 2182_002v000 4 36 May 2011 ...
Страница 192: ...Connecting link to the network Chapter 6 Configuration and alignment phn 2182_002v000 6 36 May 2011 ...
Страница 234: ...Testing the radio link Chapter 8 Troubleshooting phn 2182_002v000 8 14 May 2011 ...