background image

7A

7B

EN

EN

05

 • Press cmd for 3 sec

and the location will be

empty.

The display will blink

and the position will

be free.

02

 • The display will show 

dL,

 confirming that all 

remote controls have been 

erased.

01

 • Press the cmd button 

for 5 sec.

01

 •  Press the

cmd button for

1 sec.

          

Remote controls

 programming for total opening.

Remote controls programming for pedestrian opening.

02

 • Select the 

function (SU or 

SP) use

↓↑.

03

 • Press cmd

once to remote 

control (SU or SP). 

04

 •  Use ↓↑

to select the

remote control

location you want

to delete.

04

 • The first free

position appears. 

05

 • Press the remote 

control button you want 

to program. The display 

will blink and move to 

the next free location.

03

 • Press cmd

once to confirm 

the function (SU 

or SP).

01

 • Press the

cmd button for

1 sec.

02

 • Select the 

function where you 

want to program 

the remote control 

(SU or SP) use 

↓↑.

• PROGRAMMING REMOTE CONTROLS

• ERASE ALL THE REMOTE CONTROL

• ERASE REMOTE CONTROLS

 If you do not press any button for 10 sec.

the control board will return to standby

Whenever you store or delete a 

the display will flash and show the next po-

sition. You can add or delete remote control, 

without needing back to point 01.

• Use ↓↑ to navigate 

through the menus.

• To access the P menu 

press the MENU button 

for 2 sec.

The functions of the control board are divided into 2 areas:

• 

Main Menus "P" 

• 

Extra Menus "E"

• Press MENU when 

you want to confirm 

access to a menu.

• Press ↓↑

 simultaneously to 

exit programming.

REMOTE CONTROLS

FUNCTIONS 

03. INSTALLATION

03. INSTALLATION

• Use ↓↑ to navigate 

through the menus.

• To access the E menu 

press the MENU button 

for 10 sec.

• Press MENU when 

you want to confirm 

access to a menu.

• Press ↓↑ 

simultaneously to 

exit programming.

We can only go into programming with the gate electrically stumbled.

P MENU

E MENU

Содержание MC62

Страница 1: ...v1 5 REV 02 2022 MC62 MC62 EN USER S AND INSTALLER S MANUAL...

Страница 2: ...UNCTIONS MENU E P0 COURSE PROGRAMMING P1 DECELERATION TIME ADJUSTMENT E2 COURTESY LIGHT TIME P7 OPERATING LOGIC P4 PAUSE TIME AND DOORS DELAY E6 DECELERATION SPEED P2 FORCE AND SENSITIVITY ADJUSTMENT...

Страница 3: ...ant Read all instructions carefully before beginning the installation usage procedures and keep this manual in a safe place that it can be consulted whenever necessary This product is intended for use...

Страница 4: ...tral from the bottom If the automatism is to be installed at a height of more than 2 5m from the ground or other level of access the minimum safety and health requirements for the use of work equipmen...

Страница 5: ...automation of 24V swing gates Power Supply 20 24V AC Flashing light s output 24VDC 4W Max RGB Flashing light s output 24Vdc 100mA Max Motor s output 24Vdc 2 x 120W Max Auxiliary accessories output 24V...

Страница 6: ...on the display 04 Make a course programming menu P0 page 9A 05 If necessary adjust the deceleration time of the gate at opening and closing menu P1 page 10A 06 Adjust the gateforce and sensivity menu...

Страница 7: ...n where you want to program the remote control SU or SP use PROGRAMMING REMOTE CONTROLS ERASE ALL THE REMOTE CONTROL ERASE REMOTE CONTROLS If you do not press any button for 10 sec the control board w...

Страница 8: ...light 00 11B Remote programming Distance PGM OFF Distance PGM ON 00 11B MENU FUNCTION MAX MIN PROGRAMMABLE STATE FACTORY VALUE PAGE Human Present Desactivates human present Activates human present 00...

Страница 9: ...G P FORCE AND SENSIVITY ADJUSTMENT DIRECTION OF DISPLAY ROTATION COURSE PROGRAMMING OF TWO MOTORS Normal rotation leaf 1 starts opening normal speed Slow rotation leaf 1 goes into opening slowdown slo...

Страница 10: ...ax 25s 0s min max 25s 01 Press MENU for 2 sec until it appears 02 Use UP until appears 03 Press Menu will appear Use UP or DW to navigate the parameters 04 Press MENU to edit the chosen parameter valu...

Страница 11: ...rder the movement is reversed Step by step mode 1st impulse OPEN 2nd impulse STOP 3rd impulse CLOSE 4th impulse STOP If it is fully open and timed it closes Condominium Mode Does not respond to orders...

Страница 12: ...ull closing Full opening 00 OFF Pedestrian maneuvers Total maneuvers 01 Press MENU for 10 sec until it appears 02 Press MENU until it appears Use UP or DW to navigate the parameters 03 Press MENU to e...

Страница 13: ...m current value provided by the control board 00 disable opening push 01 active opening push Allows you to activate the opening stroke ram 00 disables closing push 01 active closing push Allows you to...

Страница 14: ...hundred thousand Continuous light Flashing light Default value 00 When resetting all factory values will be reset The memorized remote controls and the maneuver counter will always have the memorized...

Страница 15: ...ocell Full opening button pressed Obstructed photocell Pedestrian opening button pressed In pause time Control board performs the opening course In time of pedestrian pause Control board performs the...

Страница 16: ...w the same steps until you find all the problems B START SYSTEMS 1 Disconnect all wires connected to the START connector 2 If the LED turned OFF try reconnecting one device at a time until you find th...

Страница 17: ...TIONS MAP Full Opening Partial Opening Flashing Lamp 12 24VD 4W Max Power Supply Transformer 230Vac or 110Vac 50 60Hz 120W Max Solar panel Electric Lock 12 24VDC 12W Max Photocell Set Antenna RGB flas...

Отзывы: