07. TROUBLESHOOTING

INSTRUCTIONS FOR FINAL CONSUMERS / TECHNICIANS

Anomaly

Procedure

Behavior

Procedure II

Discovering the origin of the problem

• Motor 

doesn’t 

work.

• Make sure you 

have power supply 

connected to control 

board and if it is 

working properly.

• Still not working.

• Consult a qualified 

MOTORLINE technician.

• Motor 

doesn’t 

move but 

makes 

noise.

• Unlock motor 

and move the gate 

by hand to check 

for mechanical 

problems on the 

movement.

• Is the gate stuck?

• Consult a qualified gates 

technician.

1 • Check all motion axis and associated motion systems related with the gate and automatisme (rails, pulleys, bolts, hinges, etc) to find out 

what is the problem.

• The gate moves 

easily?

• Consult a qualified 

MOTORLINE technician.

• Motors 

open but 

doesn’t 

close.

• Unlock motor(s) 

and move the roller 

by hand to closed 

position. Block 

the motor again 

and turn off power 

supply for 5 seconds. 

Reconnect it and 

send order to open 

gate using remote 

control.

• Gate opened but 

didn’t close again. 

1 • Check if there is any 

obstacle in front of the 

photocells; 

2 • Check if any of the 

control devices (Key 

Selector, Pushbutton, Video 

Intercom, etc.) are stucked 

and sending permanent 

signal to control board;

3 • Consult a qualified 

MOTORLINE technician.

• Motor 

doesn’t 

make 

complete 

course.

• Unlock motor 

and move gate 

by hand to check 

for mechanical 

problems on the 

gate. 

• Encountered 

problems?

• Consult an experienced 

gates expert.

1 • Check all motion axis and associated motion systems related with the gate and automatisme (rails, pulleys, bolts, hinges, etc) to find out 

what is the problem.

• The gate moves 

easily?

• Consult a qualified 

MOTORLINE technician. 

1 • Open control box and check if 

it has 230V power supply;

2 • Check input fuses;

3 • Disconnect motors from 

control board and test them by 

connecting directly to power 

supply in order to find out if they 

have problems (see page 11B).

4 • If the motors work, the 

problem is on the control board.

Pull it out and send it to our 

MOTORLINE technical services 

for diagnosis;

5 • If the motors don’t work, 

remove them from installation 

site and send to our MOTORLINE 

technical services for diagnosis.

1 • Check capacitors, testing 

operator with new capacitor;

2 • If capacitors are not the 

problem, disconnect motors 

from control board and it them 

by connecting directly to power 

supply in order to find out if it 

has problems (see page 11B).

3 • f the motors work, the 

problem is from control board. 

Pull it out and send it to our 

MOTORLINE technical services 

for diagnosis;

4 • If the motors don’t work, 

remove them from installation 

site and send to our MOTORLINE 

technical services for diagnosis.

1 • Check capacitors, testing with 

new capacitors;

2 • If capacitors are not the 

problem, disconnect motor 

from control board and test it 

by connecting directly to power 

supply in order to find out if it is 

broken;

3 • If the motor(s) doesn’t work, 

remove it from installation site 

and send to our MOTORLINE 

technical services for diagnosis.

4 • If motor work well and move 

gate at full force during the 

entire course, the problem is 

from controller. Set force using 

trimmer on the board. Make a 

new working time programming, 

giving suffient time for opening 

and closing with appropriate 

force (consult control board 

manual).

5 • If this doesn’t work, remove 

control board and send it to 

MOTORLINE technical services.

NOTE:

Setting force of the controller 

should be suficiente to make 

the gate open and close without 

stopping, but should stop and 

invert with a little effort from a 

person. In case of safety systems 

failure, the gate shall never cause 

physical damaged to obstacles 

(vehicles, people, etc.).

All control boards 

MOTORLINE

 have LEDs 

that easily allow to conclude which devices 

are with anomalies. All safety devices LEDs 

(Le) in normal situations remain On. All 

"START" circuits LEDs in normal situations 

remain Off. 

If LEDs devices are not all On, there is some 

security systems malfunction (photocells, 

safety edges). If "START" circuits LEDs are 

turn (Op and Cl), there is a control device 

sending permanent signal. 

A) SECURITY SYSTEMS:

1 •Close with a shunt all safety systems 

on the control board (check manual of the 

control board in question). If the automated 

system starts working normally check for

the problematic device.

2 • Remove one shunt at a time until you 

find the malfunction device.

3 • Replace it for a functional device and 

check if the motor works correctly with all 

the other devices. If you find another one 

defective, follow the same steps until you 

find all the problems.

B) START SYSTEMS:

1 • Disconnect all wires connected to the 

START connector. 

2 • If the LED turned OFF, try reconnecting 

one device at a time until you find the 

defective device.

NOTE:

In case procedures described in sections 

A

and 

B

) don’t result, remove control board and 

send to our 

MOTORLINE

 technical services 

for diagnosis.

Anomaly

Procedure

Behavior

Procedure II

Discovering the origin of the problem

• Motor 

doesn’t 

work.

• Make sure you 

have power supply 

230/110V connected 

to control  board 

and if it is working 

properly.

• Still not working.

• Consult a qualified 

technician 

MOTORLINE.

• Motor 

doesn’t 

move but 

makes 

noise.

• Unlock motor 

and move the gate 

by hand to check 

for mechanical 

problems on the 

movement.

• Is the gate stuck?

• Consult a qualified gates 

technician.

1 • Check all motion axis and associated motion systems related with the gate and automatisme (rails, pulleys, bolts, hinges, etc) to find out 

what is the problem.

• The gate moves 

easily?

• Consult a qualified 

MOTORLINE  

technician.

• Motors 

open but 

doesn’t 

close.

• Unlock motor 

and move the gate 

by hand to closed 

position. Block 

the motor again 

and turn off power 

supply for 5 seconds. 

Reconnect it and 

send order to open 

gate using remote 

control.

• Gate opened but 

didn’t close again. 

1 • Check if there is any 

obstacle in front of the 

photocells; 

2 • Check if any of the 

control devices (Key 

Selector, Pushbutton, 

Video Intercom, etc.) are 

stucked and sending 

permanent signal to 

control board;

3 • Consult a qualified 

MOTORLINE 

technician.

• Motor 

doesn’t 

make 

complete 

course.

• Unlock motor 

and move gate 

by hand to check 

for mechanical 

problems on the 

gate. 

• Encountered 

problems?

• Consult an experienced 

gates expert.

1 • Check all motion axis and associated motion systems related with the gate and automatisme (rails, pulleys, bolts, hinges, etc) to find out 

what is the problem.

• The gate moves 

easily?

• Consult a qualified 

technician 

MOTORLINE

1 • Open control box and check if 

it has 230/110V power supply;

2 • Check input fuses;

3 • Disconnect motors from 

control board and test them by 

connecting directly to a 12/24V 

battery in order to find out if 

they have problems

4 • If the motors work, the 

problem is on the control board.

Pull it out and send it to our 

MOTORLINE  

technical services 

for diagnosis;

5 • If the motors don’t work, 

remove them from installation 

site and send to our technical 

services for diagnosis.

1 • f the motors work, the 

problem is on the control board. 

Pull it out and send it to our  

MOTORLINE  

technical services 

for diagnosis;

2 • If the motors don’t work, 

remove them from installation 

site and send to our  

MOTORLINE 

technical services for diagnosis.

1 • If the motordoesn’t work, 

remove it from installation site 

and send to our 

MOTORLINE

 

technical services for diagnosis.

2 • If motor work well and move 

gate at full force during the 

entire course, the problem is on 

the control board. Set force using 

trimmer on the board. Make a 

new working time programming, 

giving suffient time for opening 

and closing with appropriate 

force (consult control board 

manual).

3 • If this doesn’t work, remove 

control board and send it to 

MOTORLINE  

technical services.

NOTE:

Setting force of the control board 

should be suficiente to make 

the gate open and close without 

stopping, but should stop and 

invert with a little effort from a 

person. In case of safety systems 

failure, the gate shall never cause 

physical damaged to obstacles 

(vehicles, people, etc.).

All control boards have LEDs that easily 

allow to conclude which devices are with 

anomalies. All safety devices LEDs (DE) in 

normal situations remain On. All "START" 

LEDs in normal situations remain Off. 

If LEDs devices are not all On, there is some 

security systems malfunction (photocells, 

safety edges). If "START" LEDs are turn (Op 

and Cl), there is a control device sending 

permanent signal. 

A) SECURITY SYSTEMS:

1 •Close with a shunt all safety systems 

on the control board (check manual of the 

control board in question). If the automated 

system starts working normally check for

the problematic device.

2 • Remove one shunt at a time until you 

find the malfunction device.

3 • Replace it for a functional device and 

check if the motor works correctly with all 

the other devices. If you find another one 

defective, follow the same steps until you 

find all the problems.

B) START SYSTEMS:

1 • Disconnect all wires connected to the 

START connector (LO and LE). 

2 • If the LED turned OFF, try reconnecting 

one device at a time until you find the 

defective device.

NOTE:

In case procedures described in sections 

A

and 

B

) don’t result, remove control board and 

send to our 

MOTORLINE  

technical services 

for diagnosis.

Содержание MC62

Страница 1: ...v1 5 REV 02 2022 MC62 MC62 EN USER S AND INSTALLER S MANUAL...

Страница 2: ...UNCTIONS MENU E P0 COURSE PROGRAMMING P1 DECELERATION TIME ADJUSTMENT E2 COURTESY LIGHT TIME P7 OPERATING LOGIC P4 PAUSE TIME AND DOORS DELAY E6 DECELERATION SPEED P2 FORCE AND SENSITIVITY ADJUSTMENT...

Страница 3: ...ant Read all instructions carefully before beginning the installation usage procedures and keep this manual in a safe place that it can be consulted whenever necessary This product is intended for use...

Страница 4: ...tral from the bottom If the automatism is to be installed at a height of more than 2 5m from the ground or other level of access the minimum safety and health requirements for the use of work equipmen...

Страница 5: ...automation of 24V swing gates Power Supply 20 24V AC Flashing light s output 24VDC 4W Max RGB Flashing light s output 24Vdc 100mA Max Motor s output 24Vdc 2 x 120W Max Auxiliary accessories output 24V...

Страница 6: ...on the display 04 Make a course programming menu P0 page 9A 05 If necessary adjust the deceleration time of the gate at opening and closing menu P1 page 10A 06 Adjust the gateforce and sensivity menu...

Страница 7: ...n where you want to program the remote control SU or SP use PROGRAMMING REMOTE CONTROLS ERASE ALL THE REMOTE CONTROL ERASE REMOTE CONTROLS If you do not press any button for 10 sec the control board w...

Страница 8: ...light 00 11B Remote programming Distance PGM OFF Distance PGM ON 00 11B MENU FUNCTION MAX MIN PROGRAMMABLE STATE FACTORY VALUE PAGE Human Present Desactivates human present Activates human present 00...

Страница 9: ...G P FORCE AND SENSIVITY ADJUSTMENT DIRECTION OF DISPLAY ROTATION COURSE PROGRAMMING OF TWO MOTORS Normal rotation leaf 1 starts opening normal speed Slow rotation leaf 1 goes into opening slowdown slo...

Страница 10: ...ax 25s 0s min max 25s 01 Press MENU for 2 sec until it appears 02 Use UP until appears 03 Press Menu will appear Use UP or DW to navigate the parameters 04 Press MENU to edit the chosen parameter valu...

Страница 11: ...rder the movement is reversed Step by step mode 1st impulse OPEN 2nd impulse STOP 3rd impulse CLOSE 4th impulse STOP If it is fully open and timed it closes Condominium Mode Does not respond to orders...

Страница 12: ...ull closing Full opening 00 OFF Pedestrian maneuvers Total maneuvers 01 Press MENU for 10 sec until it appears 02 Press MENU until it appears Use UP or DW to navigate the parameters 03 Press MENU to e...

Страница 13: ...m current value provided by the control board 00 disable opening push 01 active opening push Allows you to activate the opening stroke ram 00 disables closing push 01 active closing push Allows you to...

Страница 14: ...hundred thousand Continuous light Flashing light Default value 00 When resetting all factory values will be reset The memorized remote controls and the maneuver counter will always have the memorized...

Страница 15: ...ocell Full opening button pressed Obstructed photocell Pedestrian opening button pressed In pause time Control board performs the opening course In time of pedestrian pause Control board performs the...

Страница 16: ...w the same steps until you find all the problems B START SYSTEMS 1 Disconnect all wires connected to the START connector 2 If the LED turned OFF try reconnecting one device at a time until you find th...

Страница 17: ...TIONS MAP Full Opening Partial Opening Flashing Lamp 12 24VD 4W Max Power Supply Transformer 230Vac or 110Vac 50 60Hz 120W Max Solar panel Electric Lock 12 24VDC 12W Max Photocell Set Antenna RGB flas...

Отзывы: