background image

6A

6B

255

144

145

329

271

36

183

186.5

319.5

06

07

09

10

08

71

40

137

EN

EN

01 

• Open the protection cover to acess 

the key hole for the release.

03 

• Pull the lever towards the outside, and you can now open/close the gate manually.

02 

• Insert the key and turn it 90°.

03. OPERATOR 

03. OPERATOR 

TECHNICAL SPECIFICATIONS  

UNLOCK OPERATOR 

To open manually the gate in case of electric power failure or in case of damage, follow 

the below steps:

The specifications of the automatism 

BRAVO 500

 are as follows:

The dimensions (mm) of automatism 

BRAVO 500

 are the following:

So that the automation will operate normally, close the unlock and turn the key to the 

original position. Close the cover (

06

) to finish, make a move in order to confirm the 

functioning of the automation.

BRAVO500

BRAVO500/110

• 

Power Supply

AC 230V 50Hz

AC 110V 60Hz

• 

Power

280W

280W

• 

Speed  

0,156 m/sec

0,156 m/sec

• 

Thermal protection

120ºC

120ºC

• 

Force

1200N

1200N

• 

Working temperature

-25°C to 55°C

-25°C to 55°C

• 

Capacitor 

8µF

25µF

• 

IP protection

IP44

IP44

• 

Working frequency

25%

25%

• 

Noise level

LpA <= 56 dB (A)

LpA <= 56 dB (A)

• 

Thermal reset 

2min to complete cycle 2min to complete cycle

• 

Maximum weight of leaf

500kg

500kg

• 

Maximum size of leaf 

7m

7m

EN

EN

Содержание BRAVO500

Страница 1: ...v4 3 REV 05 2022 EN USER S AND INSTALLER S MANUAL EN BRAVO500...

Страница 2: ...icable in countries with recycling systems This marking on the product or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should...

Страница 3: ...e mechanism GENERAL WARNINGS This manual contains very important safety and usage information very important Read all instructions carefully before beginning the installation usage procedures and keep...

Страница 4: ...USERS Keep this manual in a safe place to be consulted whenever necessary If the product has contact with fluids without being prepared it must immediately disconnect from the power supply to avoid sh...

Страница 5: ...ng screws to the plate 05 04 fixing screws to the ground 06 01 fixation plate 07 02 fixation plate of the limit switches 08 01 user s manual 09 02 photocells 10 02 remote controls 11 01 Control board...

Страница 6: ...The dimensions mm of automatism BRAVO 500 are the following So that the automation will operate normally close the unlock and turn the key to the original position Close the cover 06 to finish make a...

Страница 7: ...TION 04 INSTALLATION 04 INSTALLATION SITE INSTALLATION CREATE FOUNDATION NOTE For correct operation of the automatism it is necessary to pay attention to the dimensions given in the following images A...

Страница 8: ...Mark the place to make the holes for the bushings Must make the mark at the center of the oval holes of the plate 03 Drill four holes with 18mm on foun dation Place M10 steel anchors on the holes 03 A...

Страница 9: ...er end of the rack rests on top of the pinion and weld the other spacer to the gate 06 Open the gate to support the point of the new piece of rack on top of the pinion and weld the spacer 07 Remove th...

Страница 10: ...with a level 02 Fasten the support of the rack over the pinion to the gate 03 Close the gate a bit until the other end of the rack rests on top of the pinion and fasten the other support 05 Open the...

Страница 11: ...chanical limit switch is activated when the plate is in contact with the spring The magnetic limit switch is activated when the magnet is aligned with the motor reader Fig 45 03 Move the gate to the c...

Страница 12: ...important to use stoppers on the opening and closing of the gate If this is not respected there may be danger of the gate open too much in manual mode and jump out of the rail It is important to use j...

Страница 13: ...em by connecting directly to power supply in order to find out if it has problems see page 11A 3 If the motor works the problem is from control board Pull it out and send it to our MOTORLINE technical...

Страница 14: ...y 2 To detect if the malfunction is on the control board or on the motor is sometimes necessary to perform tests with connection directly to a 110V 230V power supply For this it is necessary to interp...

Отзывы: