background image

INSTALLATION INSTRUCTIONS 

RBand

 for Doors 

MODEL:

 RB-P-K10, RB-TX10 

www.milleredge.com 

[email protected] 

800-220-3343

1/5 

WARNING

 

Read and understand all instructions before beginning installation. Disconnect power to motor and test upon completion. 
Wireless products should be installed by qualified personnel to ensure the requirements herein have been met. Keep 
these  instructions  with  the  installation.  Always  abide  by  local  and  national  electrical  code  specifications  when  wiring 
accessories to motor controls. 

The Miller Edge RBand Monitored  Wireless Door Edge System is  intended to provide  a wireless connection between a 
monitored  sensing  edge  and  a  motorized  operator  installed  with  a  garage  door  or  grille.  RBand  meets  the  UL  325 
requirements for monitored devices and has been certified as a UL 325 Recognized Component. It is designed for use with 
operators  that  comply  with  UL  325  using  a  Miller  Edge  10K  Sensing  Edge.  Consult  your  operator  manual  for  detailed 
instructions about connecting to the motor. 

KIT CONTENTS 

RBand Edge Transmitter (RB-TX10)

RBand Door Edge Receiver (RB-

P

-RX10)

(2) 3.6V AA lithium batteries*

(4) #6 pan head transmitter mounting screws

*Replacement 

3.6V AA lithium batteries

 can be purchased at your 

local electronics store or via Miller Edge.

REQUIRED 

1/8” flat blade screwdriver

1/4” flat blade screwdriver

Miller Edge 10K (T2/blue band) Sensing Edge

RECOMMENDED 

Multi-meter capable of reading 10KΩ

Mounting screws as required for receiver

I.

RECEIVER INSTALLATION

1. Turn off power to the door operator.
2. Remove Receiver cover and mount the receiver base near the operator, where it will be in line of sight with the

transmitter for the entire range of travel [IMAGE 1].

3. Connect power (12-24 VAC/DC) to the terminals marked power, noting the +/- polarity. 24 VAC power can be

connected either way not polarity sensitive [IMAGE 2].

4. Connect both PE1 and PE2 to the photo-eye inputs on the operator. N/A is not used.
5. Replace the Receiver cover and turn on power to the operator. Note: it takes ~5 seconds for the Receiver to

initialize.

Note: RBand  Door Edge Receiver is compatible with up to 3 RBand Transmitters.

IMAGE 1. Door Installation with RBand Transmitter & Receiver

 

RB-P_INST_2021

0720

 

Содержание RB-P-K10

Страница 1: ...ng to the motor KIT CONTENTS RBand Edge Transmitter RB TX10 RBand Door Edge Receiver RB P RX10 2 3 6V AA lithium batteries 4 6 pan head transmitter mounting screws Replacement 3 6V AA lithium batteries can be purchased at your local electronics store or via Miller Edge REQUIRED 1 8 flat blade screwdriver 1 4 flat blade screwdriver Miller Edge 10K T2 blue band Sensing Edge RECOMMENDED Multi meter c...

Страница 2: ...ED on R1 LED 1 edge connected Programmed Off Fault Condition On Check LED Programmed Check LED flashes every 5 seconds R2 LED Not used DIP SWITCH SETTINGS Leave switches in factory default settings all on 7 PIN CONNECTOR 12 24 VAC DC Constant power source 12 24 VAC DC Constant power source ground N A Not used PE1 P E input terminal PE2 P E input terminal N O Normally open COM Relay common ...

Страница 3: ... IMAGE 3 2 Test the sensing edge for functionality press the sensing edge and the Receiver R1 LED will turn on IV TROUBLESHOOTING If the Receiver does not react to the Transmitter you can check the RF signal strength 1 Press the check button on the Receiver for 2 seconds IMAGE 2 4 beeps will be heard You then will hear a beep every 1 1 2 seconds during the check process Wait about 30 seconds if no...

Страница 4: ...itored applications IX FCC COMPLIANCE Transmitter Model RB TX10 FCC ID U5Z RB TX10 Receiver Model RB P RX10 FCC ID U5Z RB D RX10 This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This...

Страница 5: ...not recommended and will void the manufacturer warranty XII WARRANTY RBand for Doors model RB P K10 carries a 2 year warranty from date of shipment from Miller Edge for credit or replacement This warranty applies to normal use which is found to have defective materials or workmanship as determined solely by an authorized factory representative This warranty is void where evidence of misuse or abus...

Отзывы: