© Motor City Wash Works, Inc. 48285 Frank, Wixom Michigan 48393 U.S.A.
Phone: 248.313.0272 ▪ Fax: 248. 313.0271
8MANULDNSINS003
03-21-18
www.motorcitywashworks.com
19
R UN
S TOP
R UN
E RR OR
P OWER
B AT .L OW
1
0
E
L
C
2
-P
C
12
NN
DR
C2
Y3
Y2
Y1
C1
Y0
C0
X3
X4
X6
X7
X5
s
s
X1
X2
X0
R
S-4
85
R
S-2
32
Y1
Y3
Y0
Y2
Y4
Y5
Y6
Y7
C0
X6
X7
X1
X2
X3
X4
X5
ss
X0
L .V
P OWER
E
L
C
-E
X
1
6N
ND
R
Y1
Y3
Y0
Y2
Y4
Y5
Y6
Y7
C0
X6
X7
X1
X2
X3
X4
X5
s s
X0
L .V
P OWER
E
L
C
-E
X
1
6N
ND
R
11. 750
12. 750
3
5
2
1
8
7
4
6
A2
A1
C OM
C OM
N O
N O
NC
NC
+V +V
+V
+V
DC OK
DC OK
+ V ADJ
+
N
L
D
R
Y
N
-S
H
IN
E
E
-S
TO
P
1
20
V
A
C
-2
A
2
4V
D
C
0
V
D
C
N
E
U
T
R
A
L
S
H
IE
LD
C
O
U
N
TE
R
B
A
LA
N
C
E
T
O
P
W
H
L
D
O
W
N
T
O
P
W
H
L
R
IN
S
E
1 2 3 4 5 6 7 8 9 10
13 14 15 1617
19
18
T
O
P
W
H
L
S
O
A
P
S
O
N
R
R
E
A
D
Y
P
/E
T
R
C
K
D
T
E
C
T
LI
G
H
T
T
O
P
W
H
L
H
O
O
D
S
N
S
R
S
ID
E
W
H
E
E
L
E
X
TE
N
D
S
ID
E
W
H
E
E
L
R
IN
S
E
C
/W
E
-S
TO
P
IN
D
R
Y
N
-S
H
IN
E
E
-S
TO
P
C
/W
E
-S
TO
P
O
U
T
B
E
E
FE
R
1
2
0V
A
C
20
S
ID
E
W
H
E
E
L
S
O
A
P
T
O
P
W
H
L
R
E
A
D
Y
IN
T
O
P
W
H
L
R
E
A
D
Y
IN
E
S
TO
P
O
K
IN
E
-S
TO
P
O
K
IN
S
ID
E
W
H
L
R
E
A
D
Y
IN
S
ID
E
W
H
L
R
E
A
D
Y
IN
12
11
21
2A D
UL 1077
4A D
UL 489
40A D
U L 489
20A D
UL 1077
20A D
U L 1077
2A D
UL 1077
A1
A 1
+
A2
A 2
+
2 4-
2 30V
~
_
14
14
11
11
12
12
A1
A1
+
A2
A2
+
2 4-
2 30V
~
_
14
14
11
11
12
12
A1
A 1
+
A2
A 2
+
2 4-
2 30V
~
_
14
14
11
11
12
12
A 1
A 2
12
11
14
120
VA
22
T
O
P
W
H
L
T
IL
T
S
W
IT
C
H
2A D
UL 1077
2A D
UL 1077
HIGH SIDE
DRIV ER SIDE
H IGH SIDE
P AS SE NGER S IDE
A1
A1
+
A2
A2
+
2 4-
2 30V
~_
14
14
11
11
12
12
120V
C
R
1
X
00
0
V
+
2
4
1 2 3 4 5 6 7 8 9 10 11
13 14 15 16
12
17
20
19
21
18
22
NEUTRAL
2 4VDC
0VDC
tst
2
4V
D
C
0
V
D
C
F
O
R
T
E
S
T
O
N
LY
208VAC-3PH-40AMPS
120VAC-1PH-15A
NEUTRAL
CB4
CB1
208VA C-3P HASE
2 0 8V M AI N DISCONNECT
1
2
0
V
M
AI
N
D
ISC
O
NNE
CT
L
N
G
L1
L2
L3
PENETRATE CONDUITS
TROUGH BOTTOM OF
ENCLOSURE ONLY!
DO NOT PUNCH
HOLE
ON TOP OF ENCLOSURE.
DOING SO
VOID
EQUIPMENT WARRANTY!
TO REACH MAIN
BREAKERS, KEEP FEED
WIRES LEFT HAND SIDE
INSIDE CONTROL BOX.
FIELD SUPPLIED
FIELD SUPPLIED
208VA C-3P HASE
Pic #45: Electrical Supply For 208VAC Control Panel
R U N
S T O
P
R U N
E R R O
R
P O WE
R
B A T . LO
W
1
0
E
LC
2
-P
C
12
N
N
D
R
C 2
Y 3
Y 2
Y 1
C 1
Y 0
C 0
X 3
X 4
X 6
X 7
X 5
s
s
X 1
X 2
X 0
R
S
-
485
R
S
-
232
Y 1
Y 3
Y 0
Y 2
Y 4
Y 5
Y 6
Y 7
C 0
X 6
X 7
X 1
X 2
X 3
X 4
X 5
s
s
X 0
L .V
P O WE
R
E
LC
-E
X
1
6N
N
D
R
Y 1
Y 3
Y 0
Y 2
Y 4
Y 5
Y 6
Y 7
C 0
X 6
X 7
X 1
X 2
X 3
X 4
X 5
s
s
X 0
L .V
P O WE
R
E
LC
-E
X
1
6N
N
D
R
11"
13"
3
5
2
1
8
7
4
6
A2
A1
C OM
C OM
N O
N O
NC
NC
+V +V +V +V
DC OK
DC OK
+ V ADJ
+
N
L
D
R
Y
N
-S
H
IN
E
E
-S
T
O
P
1
2
0
V
A
C
-2
A
2
4
V
D
C
0
V
D
C
N
E
U
T
R
A
L
S
H
IE
LD
C
O
U
N
T
E
R
B
A
L
A
N
C
E
T
O
P
W
H
L
D
O
W
N
T
O
P
W
H
L
R
IN
S
E
1 2 3 4 5 6 7 8 9 10
13 1415 16 17
19
18
T
O
P
W
H
L
S
O
A
P
S
O
N
R
R
E
A
D
Y
P
/E
T
R
C
K
D
T
E
C
T
L
IG
H
T
T
O
P
W
H
L
H
O
O
D
S
N
S
R
S
ID
E
W
H
E
E
L
E
X
T
E
N
D
S
ID
E
W
H
E
E
L
R
IN
S
E
C
/W
E
-S
T
O
P
I
N
D
R
Y
N
-S
H
IN
E
E
-S
T
O
P
C
/W
E
-S
T
O
P
O
U
T
B
E
E
F
E
R
1
2
0V
A
C
2
4
V
D
C
0
V
D
C
20
S
ID
E
W
H
E
E
L
S
O
A
P
120V
C
R
1
X
00
0V
+2
4
T
O
P
W
H
L
R
E
A
D
Y
IN
T
O
P
W
H
L
R
E
A
D
Y
IN
E
S
T
O
P
O
K
IN
E
-S
T
O
P
O
K
IN
S
ID
E
W
H
L
R
E
A
D
Y
I
N
S
ID
E
W
H
L
R
E
A
D
Y
I
N
12
11
21
2 A D
UL1 077
A1
A 1
+
A2
A 2
+
2 4-
2 30V
~
_
1 4
14
1 1
11
1 2
12
A1
A1
+
A2
A2
+
2 4-
2 30V
~_
1 4
14
1 1
11
1 2
12
A1
A 1
+
A2
A 2
+
2 4-
2 30V
~
_
14
14
11
11
12
12
A1
A2
12
11
14
120
VA
22
T
O
P
W
H
L
T
IL
T
S
W
IT
C
H
1 2 3 4 5 6 7 8 9 10 11
1314 1516
12
17
20
19
21
18
22
NEUTRAL
24V DC
2 A D
UL1 077
2 A D
UL1 077
2 A D
UL1 077
4 A D
UL4 89
2 0A D
UL4 89
1 5A D
UL1 077
1 5A D
UL1 077
HIGH SIDE
DRIVE R SIDE
HIGH SIDE
PASSENG ER SIDE
A1
A 1
+
A2
A 2
+
2 4-
2 30V
~
_
14
14
11
11
12
12
0V DC
F
O
R
T
E
S
T
O
N
LY
tst
480VAC-3PH-20AMPS
120VAC-1PH-15A
N EUTRAL
C B4
C B1
480V A C-3PHASE
480V A C-3PHASE
480V MA IN DISCONNECT
12
0V
M
A
IN
D
ISC
ON
NE
CT
L
N
G
L1
L2
L3
PENETRATE CONDUITS
TROUGH BOTTOM OF
ENCLOSURE ONLY!
DO NOT PUNCH
HOLE
ON TOP OF ENCLOSURE.
DOING SO
VOID
EQUIPMENT WARRANTY!
TO REACH MAIN
BREAKERS, KEEP FEED
WIRES LEFT HAND SIDE
INSIDE CONTROL BOX.
FIELD SUPPLIED
FIELD SUPPLIED
Pic #46: Electrical Supply For 480VAC Control Panel