background image

15

16

7. 

Plug in the power cord (K).

 

CAUTION!

 

Use a dedicated circuit.

 

For best performance and reliable starting, the air compressor should be plugged into a dedicated 
circuit, as close as possible to the fuse box or circuit breaker.

 

The compressor will use the full capacity of a typical 15 A household circuit. If any other electrical 
devices are drawing from the compressor’s circuit, the air compressor may fail to start. Low voltage or 
an overloaded circuit can result in sluggish starting that causes the motor overload protection system or 
circuit breaker to trip, especially in cold conditions.

NOTE:

 A circuit breaker is recommended. If the air compressor is connected to a circuit protected by 

a fuse, use dual element time delay fuses (type “T” only).

8. 

Set the pressure switch (C) to the 

ON

 position. The compressor will start. Run the compressor for 30 minutes. 

If it fails, turn it off immediately and call the toll-free helpline at: 1-888-942-6686. Please note that breaking-
in the unit is only required prior to first use.

ON

9. 

After 30 minutes, turn off the pressure switch (C).

10. 

Close the tank drain valve (I) by turning it clockwise.

CLOSE

TM

MC

11. 

Set the pressure switch (C) to the 

ON

 position. The air receiver will fill to “cut-out” pressure and then the 

compressor’s motor will stop. The compressor is now ready for use.

Before each start-up

1.

 

Set the pressure switch (C) to the 

OFF 

position.

2.

 

Turn the air pressure regulator knob (E) counter-clockwise until it stops.

3.

 

Attach hose and accessories.

 

WARNING!

 

Risk of bursting. Too much air pressure causes a hazardous risk of bursting. 

Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator 
outlet pressure must never exceed the maximum pressure rating.

4.

 

Check and verify the motor oil level in the pump.

How to start

 

WARNING!

 

If the pump has been transported or turned upside down (even partially), allow 

the pump to sit in a normal, upright position for approximately 10 minutes before starting.

1.

 

Close the tank drain valve (I).

2.

 

Plug in the power cord (K).

3.

 

Set the pressure switch (C) to the 

ON

 position and allow tank pressure to build. Motor will stop when tank 

pressure reaches “cut-out” pressure.

4.

 

Turn the air pressure regulator knob (E) clockwise until desired pressure is reached.

5.

 

The compressor is ready for use.

 

WARNING!

 

High temperatures are generated by the electric motor and the pump. To prevent 

burns or other injuries, DO NOT touch the air compressor while it is running. Allow it to cool 
before handling or servicing. Keep children away from the air compressor at all times.

OPERATING INSTRUCTIONS (cont.)

OPERATING INSTRUCTIONS (cont.)

058-7949-6-Air-Compressor-5G-EN-05.indd   15-16

5/14/12   11:14 AM

Содержание 058-7949-6

Страница 1: ...ntains important information for your safety as well as operating and maintenance advice Keep this instruction manual for future use Should this product be passed on to a third party this instruction...

Страница 2: ...he pump oil level Perform this routinely to prevent the motor from seizing STEP 5 Close the tank drain valve located on the bottom of the air tank CLOSE TM MC STEP 6 Plug in the power cord Caution Con...

Страница 3: ...hat may result in moderate injury or damage to equipment IMPORTANT Installation operation or maintenance information that is important but not hazard related Safety Advice DANGER 1 RISK OF FIRE OR EXP...

Страница 4: ...or worn spots every week and replace them if necessary 4 Always wear hearing protection when using an air compressor Failure to do so may result in hearing loss 5 Do not carry the compressor while it...

Страница 5: ...to decrease the pressure WARNING Do not exceed the tool s maximum working pressure F TANK PRESSURE GAUGE The gauge measures the pressure level of the air that is stored in the tank It cannot be adjus...

Страница 6: ...peak induction motor for quiet operation and a cast iron oil lubricated pump for long lasting reliable performance The procedures described in this manual are solely for this 5 gallon 18 9 L air compr...

Страница 7: ...air compressor near an electrical outlet b The compressor must be at least 12 31 cm from any wall or obstruction in a clean well ventilated area to ensure sufficient air flow and cooling c Place the...

Страница 8: ...Do not operate the compressor if the oil is over filled or under filled 2 Oil is added by removing the oil plug M and using a funnel to avoid spills adding oil to the compressor J K L Max Min L Hex h...

Страница 9: ...nd then the compressor s motor will stop The compressor is now ready for use Before each start up 1 Set the pressure switch C to the OFF position 2 Turn the air pressure regulator knob E counter clock...

Страница 10: ...through the oil sight glass The pump oil level must be within the red circle Do not overfill or underfill Daily Check the valve Pull activate the safety valve daily to ensure that it is operating pro...

Страница 11: ...itch to the ON position The extension cord is the wrong wire gauge or is too long Check Technical Specifications page 3 for the proper wire gauge and cord length The motor s thermal overload protectio...

Страница 12: ...re is condensation in the air tank caused by a high level of atmospheric humidity or because the air compres sor has not been running long enough Drain the air tank after each use Drain the air tank m...

Страница 13: ...s become inoperative due to abuse misuse accidental damage neglect or lack of proper installation operation or maintenance as outlined in the applicable owner s manual or operating instructions or whi...

Страница 14: ...in connection with the sale use or inability to use this product Notice to Consumer This warranty gives you specific legal rights and you may have other rights which may vary from province to province...

Отзывы: