PROBLEM

POSSIBLE CAUSES

SOLUTIONS

The  
regulator does 
not regulate 
the pressure.

The regulator or its internal parts are 
dirty or damaged.

Replace the regulator.

The pressure 
is low or there 
is not enough 
air.

There is a leak at one of the  
fittings.

Check the fittings with soapy water. Tighten or reseal 
leaking fittings (apply plumber's tape on threads). Do 
not overtighten.

The tank drain valve is open.

Close the drain valve.

The air intake is restricted.

Clean or replace the air filter element.

Prolonged excessive use of air.

Decrease the amount of air used.

There is a hole in the air hose.

Check the air hose and replace it if necessary.

The tank leaks.

Replace the tank Immediately. Do not attempt to repair 
it.

The valve is leaking.

Check for worn parts and replace them if necessary.

There is 
moisture in the 
discharge air.

There is condensation in the air tank 
caused by a high level of atmospheric 
humidity or because the air compres-
sor has not been running long enough.

Drain the air tank after each use. Drain the air tank 
more often in humid weather and use an air line filter.

The  
compressor 
overheats.

The ventilation is inadequate.

Relocate the compressor to an area with cool, dry and 
well-circulated air.

Cooling surfaces are dirty.

Clean all cooling surfaces on the pump and the motor 
thoroughly.

The valve is leaking.

Replace worn parts and reassemble using new 
plumber's tape.

EXPLODED VIEW

TROUBLESHOOTING (cont.)

SCAN

&

LEARN

NUMÉRISEZ

ET

APPRENEZ

Shop smarter on your smartphone

Get the free app at/Obtenez l’application gratuite sur :

canadiantire.ca/mobileapp

Balayez le code à barres pour obtenir plus de renseignements 

sur les compresseurs et les outils pneumatiques. 

Facilitez vos achats avec 

votre téléphone intelligent

Scan barcode for more information on compressors and air tools.

058-7949-6-Air-Compressor-5G-EN-05.indd   21-22

5/14/12   11:14 AM

Содержание 058-7949-6

Страница 1: ...ntains important information for your safety as well as operating and maintenance advice Keep this instruction manual for future use Should this product be passed on to a third party this instruction...

Страница 2: ...he pump oil level Perform this routinely to prevent the motor from seizing STEP 5 Close the tank drain valve located on the bottom of the air tank CLOSE TM MC STEP 6 Plug in the power cord Caution Con...

Страница 3: ...hat may result in moderate injury or damage to equipment IMPORTANT Installation operation or maintenance information that is important but not hazard related Safety Advice DANGER 1 RISK OF FIRE OR EXP...

Страница 4: ...or worn spots every week and replace them if necessary 4 Always wear hearing protection when using an air compressor Failure to do so may result in hearing loss 5 Do not carry the compressor while it...

Страница 5: ...to decrease the pressure WARNING Do not exceed the tool s maximum working pressure F TANK PRESSURE GAUGE The gauge measures the pressure level of the air that is stored in the tank It cannot be adjus...

Страница 6: ...peak induction motor for quiet operation and a cast iron oil lubricated pump for long lasting reliable performance The procedures described in this manual are solely for this 5 gallon 18 9 L air compr...

Страница 7: ...air compressor near an electrical outlet b The compressor must be at least 12 31 cm from any wall or obstruction in a clean well ventilated area to ensure sufficient air flow and cooling c Place the...

Страница 8: ...Do not operate the compressor if the oil is over filled or under filled 2 Oil is added by removing the oil plug M and using a funnel to avoid spills adding oil to the compressor J K L Max Min L Hex h...

Страница 9: ...nd then the compressor s motor will stop The compressor is now ready for use Before each start up 1 Set the pressure switch C to the OFF position 2 Turn the air pressure regulator knob E counter clock...

Страница 10: ...through the oil sight glass The pump oil level must be within the red circle Do not overfill or underfill Daily Check the valve Pull activate the safety valve daily to ensure that it is operating pro...

Страница 11: ...itch to the ON position The extension cord is the wrong wire gauge or is too long Check Technical Specifications page 3 for the proper wire gauge and cord length The motor s thermal overload protectio...

Страница 12: ...re is condensation in the air tank caused by a high level of atmospheric humidity or because the air compres sor has not been running long enough Drain the air tank after each use Drain the air tank m...

Страница 13: ...s become inoperative due to abuse misuse accidental damage neglect or lack of proper installation operation or maintenance as outlined in the applicable owner s manual or operating instructions or whi...

Страница 14: ...in connection with the sale use or inability to use this product Notice to Consumer This warranty gives you specific legal rights and you may have other rights which may vary from province to province...

Отзывы: