B.  AIR COMPRESSOR PUMP:

 The pump compresses the air and discharges it into the tank via the piston that 

moves up and down in the cylinder.

C.  PRESSURE SWITCH:

 This switch turns the compressor on and off. It is operated manually and when it is in the 

ON position, it allows the motor to start if the pressure in the air tank is below the factory set cut-in pressure, 
and allows the motor to stop if the pressure in the air tank reaches the factory set cut-out pressure. Be sure 
to set this switch to the OFF position when the compressor is not being used and before unplugging the 
compressor.

D.  SAFETY VALVE:

 This valve is used to prevent system failure by draining pressure from the system when it 

reaches a preset level if the pressure switch has not shut down the motor. It will pop open automatically, or it 
can be activated manually by pulling the ring on the valve.

E.  AIR PRESSURE REGULATOR:

 The regulator is used to adjust the pressure inside the line to the tool that is 

being used. Turn the knob clockwise to increase the pressure and counter-clockwise to decrease the pressure.

 

[  

WARNING!

 

Do not exceed the tool’s maximum working pressure.

F.  TANK PRESSURE GAUGE: 

The gauge measures the pressure level of the air that is stored in the tank. It cannot 

be adjusted by the operator and it does not indicate the pressure inside the line.

G.  OUTLET PRESSURE GAUGE: 

The gauge measures the regulated outlet pressure.

H.  AIR OUTLET:

 The outlet is connected to the 1/4” (6.4 mm) NPT air hose.

I.  AIR TANK DRAIN VALVE:

 The drain valve is used to remove moisture from the air tank after the compressor is 

shut off.

 

[  

WARNING!

 

Do not attempt to open the drain valve when there is more than 

   

10 PSI of air pressure in the tank.

J.  AIR TANK:

 The tank is where the compressed air is stored.

AIR TANK

DRAIN VALVE (I)

PRESSURE 

SWITCH (C)

AIR PRESSURE 

REGULATOR (E)

SAFETY 

VALVE (D)

OUTLET PRESSURE

GAUGE (G)

TANK PRESSURE

GAUGE (F)

AIR OUTLET (H)

POWER CORD (K)

AIR TANK (J)

KEY PARTS LIST

KEY PARTS DIAGRAM

ELECTRIC 

MOTOR (A)

AIR COM PRESSOR 

PUMP (B)

OIL PLUG (M)

OIL SIGHT (L)

058-7949-6-Air-Compressor-5G-EN-05.indd   7-8

5/14/12   11:14 AM

A.  ELECTRIC MOTOR:

 The motor is used to power the pump. It is equipped with at thermal overload protector. 

If the motor overheats for any reason, the thermal overload protector will shut it down in order to prevent the 
motor from being damaged.

Содержание 058-7949-6

Страница 1: ...ntains important information for your safety as well as operating and maintenance advice Keep this instruction manual for future use Should this product be passed on to a third party this instruction...

Страница 2: ...he pump oil level Perform this routinely to prevent the motor from seizing STEP 5 Close the tank drain valve located on the bottom of the air tank CLOSE TM MC STEP 6 Plug in the power cord Caution Con...

Страница 3: ...hat may result in moderate injury or damage to equipment IMPORTANT Installation operation or maintenance information that is important but not hazard related Safety Advice DANGER 1 RISK OF FIRE OR EXP...

Страница 4: ...or worn spots every week and replace them if necessary 4 Always wear hearing protection when using an air compressor Failure to do so may result in hearing loss 5 Do not carry the compressor while it...

Страница 5: ...to decrease the pressure WARNING Do not exceed the tool s maximum working pressure F TANK PRESSURE GAUGE The gauge measures the pressure level of the air that is stored in the tank It cannot be adjus...

Страница 6: ...peak induction motor for quiet operation and a cast iron oil lubricated pump for long lasting reliable performance The procedures described in this manual are solely for this 5 gallon 18 9 L air compr...

Страница 7: ...air compressor near an electrical outlet b The compressor must be at least 12 31 cm from any wall or obstruction in a clean well ventilated area to ensure sufficient air flow and cooling c Place the...

Страница 8: ...Do not operate the compressor if the oil is over filled or under filled 2 Oil is added by removing the oil plug M and using a funnel to avoid spills adding oil to the compressor J K L Max Min L Hex h...

Страница 9: ...nd then the compressor s motor will stop The compressor is now ready for use Before each start up 1 Set the pressure switch C to the OFF position 2 Turn the air pressure regulator knob E counter clock...

Страница 10: ...through the oil sight glass The pump oil level must be within the red circle Do not overfill or underfill Daily Check the valve Pull activate the safety valve daily to ensure that it is operating pro...

Страница 11: ...itch to the ON position The extension cord is the wrong wire gauge or is too long Check Technical Specifications page 3 for the proper wire gauge and cord length The motor s thermal overload protectio...

Страница 12: ...re is condensation in the air tank caused by a high level of atmospheric humidity or because the air compres sor has not been running long enough Drain the air tank after each use Drain the air tank m...

Страница 13: ...s become inoperative due to abuse misuse accidental damage neglect or lack of proper installation operation or maintenance as outlined in the applicable owner s manual or operating instructions or whi...

Страница 14: ...in connection with the sale use or inability to use this product Notice to Consumer This warranty gives you specific legal rights and you may have other rights which may vary from province to province...

Отзывы: