4.3. Overhauling
If the rotary index table is damaged, please contact
Motion Index Drives, Inc. Only repairs performed by an
MID certified technician ensures proper
functionability and optimal performance. Any
unauthorized opening of the casing will void the
warranty.
The rotary index table must be checked for play. If there
is any play in one or more stations, the cam rollers have
to be replaced.
All cam followers may have to be replaced. Check whether
the mounting holes for the cam followers in the output dial
flange are still round and true to size.
If holes are out of round the output dial flange will have to
be replaced.
4.1. Maintenance
The index tables and the gear reducer on the drive do not need to be regularly filled with oil for the duration of their
life in normal environments and applications. If for any reason oil is drained, the filling amounts can be found in the
operating manual for the drive. The type of oil to be used is Mobilgear XP460.
Index table must be greased while running. This can be done by running lube lines to the fence or using a manual greasing
system.
Every month please lubricate using the bearing grease fittings on all TMF Series and models RT400 and larger. RT100 to TT315 in-
dex drives are maintenance free (do not require gresing). Please lubricate bearing with EP2 grease. (See lubrication chart)
Do not mix mineral lubricants with synthetic lubricants.
4.2. Inspection
The intervals specified must be adjusted to suit the conditons.
Switch the drive off electrically and make sure it cannot restart by itself.
Every six months visually inspect for damage. Remove any deposit of dust (especially on the ventilation grille of the
motor) and examine the electrical cables for damage.
Every six months check the rotary index table for play in the dwell position
4. Maintenance
Maintenance includes inspections, servicing and overhauling. Maintenance work may only be undertaken by an ex-
perienced specialists.
Before working on the rotary index table and related tooling, switch the drive off electrically and make sure it cannot restart by its-
elf. Proper lockout procedures must be followed.