background image

6

RED

100 SERIES

1.5 Operation

When using the biological microscope, please pay attention to the following safety instructions:

• If it is used for any purpose other than the specified ones, including any individual component or part, the manu-

facturer will not take any responsibility.

• After-sales service or repair done by unauthorized personnel will void the warranty.
• Anyone who uses the instrument should receive instruction on the proper handling of the instrument and safety 

practices for microscopy. The biological microscope shall be placed only on a firm, flat workbench for operation.

• Since the biological microscope is a precision instrument, improper operation will impair or spoil its performance.
• The power unit is integrated in the main unit of the biological microscope: the grid supply voltage is within 

100-240V~50Hz.

The biological microscope must be connected only to the normal power socket with  
a grounding terminal. Any extension cord without ground protection is not allowed to avoid 
failure of the protection function.

If there is any electrical failure (of the fuse system, ground protection or transformer), 
turn off and unplug the unit immediately. Make sure the microscope is set aside so it will 
not be used again and contact the Motic service department or a Motic microscope repair 
agency to have it repaired.

Please be sure to turn off the power before opening the instrument to replace LED  
illuminator or replace the fuse! Only use a fuse for the rated current.

Safety instructions for the use of immersion oil.
• Immersion oil is irritating to skin; avoid contact with skin, eyes and clothing.
• Skin contact: wash with soap and plenty of water until the immersion  

oil is completely removed.

• Eye contact: flush immediately with plenty of water for at least 5 minutes.  

If irritation persists, seek medical advice.

• Dispose of immersion oil properly. Do not discharge into surface water or sewage.

The biological microscope is not equipped with any special device to protect against corrosive, latent infective, 
toxic, radioactive or other hazardous samples. Therefore, when examining any such sample you must comply with 
the relevant laws and regulations, in particular the provisions related to accident prevention.

Содержание RED100 Series

Страница 1: ...Instructions Manual English Motic Incorporation Ltd RED100 SERIES...

Страница 2: ......

Страница 3: ...warranty 07 2 Instrument description 09 2 1 General views 09 2 2 Part names 10 2 3 Application 12 2 4 Instrument and its major features 12 3 First time use operation 13 3 1 First time use 13 3 2 Opera...

Страница 4: ......

Страница 5: ...g to the EN 61010 1 2001 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use 1 3 Unpacking transportation storage The original shipping container a foam box in a fi...

Страница 6: ...f the protection function If there is any electrical failure of the fuse system ground protection or transformer turn off and unplug the unit immediately Make sure the microscope is set aside so it wi...

Страница 7: ...found notify the manufacturer immediately Upon receipt of the Notification of Defect as described above the manufacture is responsible to solve the problem either by repairing the defective instrumen...

Страница 8: ......

Страница 9: ...RUMENT DESCRIPTION RED 130 131 132 RED 120 Cordless model with rechargeable batteries included RED 100 101 Monocular Head Monocular Head Eyepiece Binocular Head Monocular Head Dual View Monocular Head...

Страница 10: ...head 9 Base w rechargeable batteries and external charger 3 Lock screw of eyepiece 10 Head lock screw 4 Triple nosepiece 11 Arm 5 4X 10X 40X objectives 12 Fine focus knob 6 Movable stage 13 Coarse fo...

Страница 11: ...X 40X 100X objectives 22 Coaxial coarse and fine focus knob 16 Mechanical stage 17 1 25 condenser w iris diaphragm 18 Stage adjustment knob X axis 19 Stage adjustment knob Y axis 20 Base w rechargeabl...

Страница 12: ...mpact and easy to use Separate coarse and fine focus adjustment Models RED 100 101 120 Coaxial coarse and fine focus adjustment Models RED 130 131 132 110mm 110mm gliding stage with linked slide clips...

Страница 13: ...transportation Connect the charger to the power supply Before plugging in keep in mind that the working voltage of the biological microscope shall be the same as the supply voltage Figure 1 Rotate the...

Страница 14: ...f its range Rotate the brightness control to the desired illumination Always begin examination using the low power objective Position the ob jective as close to the specimen as possible and focus by s...

Страница 15: ...ifications Figure 6 Lower the stage completely with the coarse focus knob Rotate the nosepiece to move the objective to be replaced to the side Unscrew the objective and remove it downward Fix the new...

Страница 16: ...to the slot Rotate the nosepiece to lock into the slot Condenser is not set properly Set the condenser properly Aperture iris diaphragm is not set accurately Set the aperture iris diaphragm accurately...

Страница 17: ...midity 10 40 C Below 31 C max humidity is 80 at 40 C linearly decreases to 50 Operation Permissible environment temperature Permissible relative humidity 5 40 C Below 31 C max humidity is 80 at 40 C l...

Страница 18: ...echanical tube length 160mm Mechanical stage RED 120 130 131 132 Dimension L x W Stroke L x W Position of vernier Slide clip 1 25 condenser 120x120mm 76x26mm On the right On the left of movable clip U...

Страница 19: ......

Страница 20: ...ouse 311 Gloucester Road Causeway Bay Hong Kong Tel 852 2837 0888 Fax 852 2882 2792 Motic Spain S L U Spain Pol Ind Les Corts C Les Corts 12 08349 Cabrera de Mar Barcelona Spain Tel 34 93 756 6286 Fax...

Отзывы: