6.4  Storage Environment 

●  Temperature: 0°C ~ +40°C 
●  Humidity: 10% ~ 90% (No condensation)   
●  Transportation (equipment stored in the package): Allows the ambient temperature of -40°C to   
 

+70°C and a humidity of 10% to 90% (no condensation). The digital slice scanning is a high- 

 

precision device, and transport protection such as avoid sun exposure, stay dry, Fragile Handle with 

 

care should be taken. If you need to pack the equipment for long-distance transportation, please 

 

contact the manufacturer (see back cover) or Motic Distributor. 

 

6.5  Digital Camera System Specifications 

Resolution 

4096 x 3000 

Pixel Dimension 

1.85 x 1.85µm 

Port 

USB 3.0 

Working Temperature 

+5°C to +40°C 

Storage Temperature 

-20° to +40°C 

 

6.6  Shifting of Instrument 

●  When moving the devices, unplug all power cable, USB 3.0 cable. 
●  Lift equipment base plate on both sides respectively, during lifting and handling process, need to 
 

keep balance of device to prevent rollover. 

 

** Attention: MoticEasyScan Pro 6N net weight: approximately 16KG.   

●  If you need to pack MoticEasyScan Pro 6N for long distance transportation, please contact Motic or 
the   Motic Distributor. 
 
 
 
 
 
 
 
 
 

(Fig. 13) 

Содержание MoticEasyScan Pro 6N

Страница 1: ...provided by the equipment may be impaired Note Complete reading of this manual before opeartion is required MoticEasyScan Pro 6N Instruction Manual Changes or modifications not expressly approved by t...

Страница 2: ...ce Hosting Ports Description 8 2 2 4 2 Computer Ports Description 9 2 2 5 System Connection Operation 9 2 3 Slide Tray 11 2 3 1 Slide Placement Procedure 12 2 3 1 1 Slide Loading Procedure 12 2 3 1 2...

Страница 3: ...bration 35 5 2 1 Calibration 35 5 2 1 1 Import Calibration File 35 5 2 1 2 Auto Calibration 37 5 2 1 3 Manual Calibration 38 5 3 Trouble Shooting 44 6 Appendix 45 6 1 Specifications 45 6 2 Electrical...

Страница 4: ...e safety signs to always operate the device the most secure way Labels Meaning l Main switch ON Main switch OFF AC Caution Pinching Hand No Use Warranty void if seal broken Warning Please do not enter...

Страница 5: ...and GB4793 1 2007 safety standards for electrical measurement control adjustment and laboratory device Electromagnetic is compatible to the standard of GB 18268 1 2010 IEC 61326 1 2005 IEC 61326 2 6...

Страница 6: ...ase note the following warranty for MoticEasyScan Digital Slide Scanning System Manufacturer warranty for material and product quality starts at the time of delivery In case of malfunction please info...

Страница 7: ...digital slide scanning software Easyscanner It is applicable for scanning digital storage transferring and browsing of histopathology slide cytology and biology slides etc 2 1 1 Intend use MoticEasyS...

Страница 8: ...7 2 2 2 System Installation Before installation please be familiar with following parts USB 3 0 cable Power Supply Cable Fig 2 2 2 3 System Connection Diagram Fig 3...

Страница 9: ...iption 2 2 4 1 Device Hosting Ports Description MoticEasyScan Pro 6N Connect the USB 3 0 of the MoticEasyScan Pro 6N to the USB 3 0 of your computer the USB 3 0 port is usually blue or next to it whic...

Страница 10: ...er should be USB3 0 port which is signed with SS or marked as blue color Computer Port Diagram Fig 5 2 2 5 System Connection Operation Please make sure the EVA foam Fig 6 which is inside the MoticEasy...

Страница 11: ...nd remove the U shape panel Fig 7a Then slide the front panel out in horizontal direction from the device Fig 7b Cut the nylon cable tie Remove the EVA foam carefully Fig 7b Slot the front panel and t...

Страница 12: ...nner and connect the other end to a safety rated Power outlet 2 3 Slide Tray Fig 8a 2 3 1 Slide Placement Procedure 2 3 1 1 Slide Loading Procedure a Hold the edge of the sides with the thumb and inde...

Страница 13: ...12 Note Ensure the backside of clip Fig 8b and Fig 8b are pressed on the top of the slide Try not to touch the cover glass on the slide during the whole process Fig 9a Fig 9b Fig 9c...

Страница 14: ...oad the slide by pushing the slide towards the direction of clip Fig 8b until the other end of the slide can be lifted Fig 10a b Lift the slide upward to move out of the slide position Fig 10b Note Tr...

Страница 15: ...ver load the slide tray with the direction shown in the figure and make sure the top surface of slide tray fits below marked line Fig 11a b After inserting the slide tray ensure the triangle arrow of...

Страница 16: ...FTWARE INSTALLATIONS AND INSTRUCTIONS 3 1 Software Installation a Double click Setup exe file in the installation program b Select installation language and click on the Next button c Then click Next...

Страница 17: ...16 d Select installation path and click Next button e Select the database installation path and click the next button f Click Install button to proceed installation and display installation process...

Страница 18: ...17 g When installation is completed click Finish button to complete software installation...

Страница 19: ...Driver Installation for Main camera a Find the camera in the Device manager then click Update Driver Software b Click Browse my computer for driver software c Click Browse select Drivers PointGrey in...

Страница 20: ...re being copied to your computer e When the installation is completed close the window in the following figure to complete the driver installation To ensure the proper work of your device please resta...

Страница 21: ...mera shows under the PC Device manager then click Update Driver Software b Click Browse my computer for driver software c Click Browse select the installation package of Motic EasyScanner then find Mo...

Страница 22: ...21 d Click Install button e The files are being copied to your computer f Click Close button To ensure the proper work of your device please restart your computer...

Страница 23: ...0 shows under the PC Device manager then click Update Driver Software b Click Browse my computer for driver software c Click Browse select the installation package of Motic EasyScanner then find Moti...

Страница 24: ...23 d Click Install button e The files are being copied to your computer f Click Close button To ensure the proper work of your device please restart your computer...

Страница 25: ...Serial Port driver a U Port 1110 driver shows under the PC Device manager then click Update Driver Software b Click Browse my computer for driver software c Click Browse select Drivers Moxa in the in...

Страница 26: ...are being copied to your computer e Click Close button To ensure the proper work of your device please restart your computer f MOXA USB Serial Port shows under the PC Device manager then click Update...

Страница 27: ...26 g Click Browse my computer for driver software h Click Browse select Drivers Moxa in the installation package and click Next button i The files are being copied to your computer...

Страница 28: ...icon on the desktop to run the software and the following interface will display This is simplified operation interface software initial status Scan button is in grey After loading the slide tray Scan...

Страница 29: ...and take the slide tray out e Settings For setting the Magnification Mode 20x or 40x Scanning Mode Scanning Profile Once the setting is complete it will be the default setting The system boot up will...

Страница 30: ...0X is the default magnification and can be changed in the settings h Scanning Mode Selection Frame Can select standard high precision EDF extension and Z stacking standard is the default mode i Scanni...

Страница 31: ...ge path scanned magnification and scan mode if needed After clicking Scan button the batch scanning will be performed based on interface settings When scanning is completed a message will be displayed...

Страница 32: ...31 a Create New Slide In the tool bar click and a window will be popped up type in corresponding slide name and description select encode method and slide storage path click confirm button...

Страница 33: ...t button on the map to cancel modeling area and the red frame will be disappeared Set modeling point system will automatically display modeling number on the modeling numbers based on scanned tissue d...

Страница 34: ...he section of the slide list column The slide browser provides multiple multiples for user selected browsing the highest viewing times are the scan multiples Users can also browse edit mark and so on...

Страница 35: ...rules or contact manufacturer or local distributor for further recycle process 4 2 Operation Instruction a Turn on the power switch b Start the scanning software When the software starts the mechanism...

Страница 36: ...components deformation and affecting scanning precision d During cleaning and maintenance process be careful not to drag the device which would affect the accuracy of it e Turn off the power when the...

Страница 37: ...rally backup is recommended even the MoticEasyScan Pro 6N is in a good working condition or once the calibration is completed b Go to System Calibration click Import button and select the backup calib...

Страница 38: ...required when changing the objective or poor scanned images a Auto Calibration Settings Follow the wizard select a blank spot then a tissue spot and the entire tissue region in the map b Click the Aut...

Страница 39: ...fail to auto calibrate a System Calibration Video Calibrate remove the slide first and click the Calibrate button the system will automatically execute the Exposure Background Balance White Balance Sc...

Страница 40: ...ure the tray is properly loaded slide with tissue and label then follow the calibration wizard Fig B Click Prepare Tissue Exposure on the calibration wizard window the tray will move to blank area aut...

Страница 41: ...Manually adjust the exposure bar and ensure the brightness of label is suitable Click Complete Macro Image Settings Select an area which can cover whole tissue by dragging a rectangle over it with the...

Страница 42: ...41 Fig B Fig C...

Страница 43: ...w the steps 10 and 11 Fig B Fig D Select an area which can cover whole tissue by dragging a rectangle over it with the mouse Then click Scan Map button After scanning map completed click Calibrate but...

Страница 44: ...with content focus the image move to the blank area of slide adjust exposure ensure the right half of histogram has no saturation Click Background Balance button in the blank area of slide Find a fie...

Страница 45: ...USB 3 0 camera is detected as USB2 0 Switch off the MoticEasyScan Pro 6N and restart it Many blur spot Real time focusing failed Re calibrate the focusing camera Image has tiling symptom The slide is...

Страница 46: ...de scanner resolution is 0 48 m pixel Under 40X mode scanner resolution is 0 24 m pixel Light Illumination 10W LED Main Camera 12M Pixel Communication Port USB3 0 6 2 Electrical Specification Input vo...

Страница 47: ...contact the manufacturer see back cover or Motic Distributor 6 5 Digital Camera System Specifications Resolution 4096 x 3000 Pixel Dimension 1 85 x 1 85 m Port USB 3 0 Working Temperature 5 C to 40 C...

Страница 48: ...ld not be placed in the place with direct sunlight dust mechanical vibrations high temperature or high humidity Please reference to 6 3 Working Environment and 6 4 Storage Environment Grounding Please...

Страница 49: ...them for cleaning Otherwise it will cause the paint fading or peeling Stubborn stain can be wiped with gauze moistened with soft detergent Plastic surface can only be cleaned with a soft cloth moiste...

Страница 50: ...otic Building Torch Hi Tech Industrial Development Zone Xiamen P R C Tel 86 0592 562 7866 Fax 86 0592 562 7855 2007 2020 Motic China Group Co Ltd All rights reserved Motic is a registered trademark an...

Отзывы: