APPLICATION

The SILVER250 Series biological microscope is designed for microscopic observation of thin 

specimens with transmitted, visible light.

SILVER

250

 

SERIES

 

|  05 

  

SILVER

250 SERIES

SILVER

 LINE

FIRST TIME USE

Before installing and using the biological microscope, make sure to read carefully the Safety 

Instructions.

1. When unpacking and handling, please do not touch the optical surfaces. After unpacking, 

place the biological microscope on a flat workbench and remove any foam padding or spacer 

used to prevent vibration during transportation.

2. Connect the cable/ charger to the power supply. Before plugging in, keep in mind that the 

working voltage of the biological microscope shall be the same as the supply voltage.

3. Turn on the power switch at the back of the arm.

Note: Make sure that the brightness control is in the minimum position before turning on or 

off the power switch.

4. Rotate the brightness control to the desired illumination.

5. After use, turn the brightness control to the minimum position, and then turn off the power 

and put on the dustproof cover.

6. The coarse focus tension has been set at the factory, but can be readjusted as required.

INSTRUMENT AND ITS MAJOR FEATURES

Major features of the instrument include:

• Built-in LED illumination with brightness adjustment.

• Coaxial coarse and fine focus adjustment with coarse focus tensi on control.

• 75mm x 50mm mechanical stage with slide clips.

• Quadruple revolving nosepiece with ball bearings, thread pitch 0.8”.

• Objectives: 4X, 10X, 40X and 100X (oil immersion), applicable for brightfield, applicable 

for darkfield (10X and 40X) and Phase contrast objectives 10X and 40X.

• Field number of 10X eyepiece is 20; high point design for observers with glasses.

•Ergonomically designed binocular tubes with observation angle of 30°; adjustable interpu-

pillary distance

FIRST TIME TO USE & OPERATION

Содержание 1100104800031

Страница 1: ...SILVER250 SERIES INSTRUCTION MANUAL ENGLISH SILVERLINE...

Страница 2: ...uch the optical lens surfaces WASTE DISPOSAL Important Any damaged biological microscope must not be treated as general waste it should be disposed of according to relevant regulations OPERATION When...

Страница 3: ...ive latent infective toxic radioactive or other hazardous samples Therefore when examin ing any such sample you must comply with the relevant laws and regulations in particular the provisions related...

Страница 4: ...SERIES 04 SILVER250 SERIES The SILVER250 Series stands out for its innovation quality and student proof features offering a wide range of microscopes for educational purposes in high schools up to adv...

Страница 5: ...he minimum position before turning on or off the power switch 4 Rotate the brightness control to the desired illumination 5 After use turn the brightness control to the minimum position and then turn...

Страница 6: ...itting properties as glass Using oil slight ly increases the resolution and brightness of the image Usually a very thin slide size 1 is used for oil immersion because at this magnification the working...

Страница 7: ...ll the correct driver IMPORTANT The next time you connect the SILVER250 Series microscope to a computer make sure the USB cable is connected to the same USB port that was used during initial installat...

Страница 8: ...for 0 17 transmitted light objective No immersion oil or non specified immersion oil for 100X oil immersion objective Aperture iris diaphragm is not set accurately Incorrect opening of aperture diaphr...

Страница 9: ...access the LED The LED is integrated on to a circuit board This LED circuit board is held into the illumina tor housing by 2 screws Remove the 2 screws from the illuminator housing to remove the LED c...

Страница 10: ...tube 30 20 Length of mechanical tube Maximum field number Hinge type interpupillary distance adjustment range Observation angle Infinite 20mm 48 to 75mm 30 Triocular tube 30 20 Length of mechanical t...

Страница 11: ...epair by unauthorized parties accident alteration shipping misuse or abuse is not covered Warranty service is provided by Motic authorized technicians Determination of warranty is at the technician s...

Страница 12: ...52 2882 2792 Motic Europe S L U Spain Pol gon Industrial Les Corts C Les Corts 12 08349 Cabrera de Mar Barcelona Spain Tel 34 93 756 6286 Fax 34 93 756 6287 CCIS is a trademark of Motic Incorporation...

Страница 13: ...he appropriate immersion oil to use IMPORTANT The working distances of the 40XRD and 100XRD objectives to the slide surface are very small and although these objectives are sealed to prevent oil conta...

Страница 14: ...f the glass The finish of the microscope is hard epoxy and is resistant to acids and reagents Clean this surface with a damp cloth and mild detergent Periodically the microscope should be disassembled...

Страница 15: ...view Is the Abbe condenser in the correct position Dust or hairs seem to be moving in the image The iris diaphragm is not open wide enough Slowly open the diaphragm to increase the size of the openin...

Отзывы: