When light rays pass through air from the specimen to the objective lens, they are distorted 

slightly, a phenomenon known as refraction. This is usually not a problem at a magnification 

of 400X or lower. However, at a magnification of 1,000X and above, refraction becomes 

problematic. This problem is reduced significantly by placing a thin layer of very clear, 

viscous oil between the slide and tip of the objective lens. The result is a much clearer image 

at 1,000X because the oil has the same light transmitting properties as glass. Using oil slight-

ly increases the resolution and brightness of the image. Usually a very thin slide (size #1) is 

used for oil immersion because at this magnification, the working distance is very small and 

is critical to focusing the specimen. Good quality glass (not plastic) cover slips should be 

used. If their thickness is over 0.17mm, the objective will not resolve properly, because the 

specimen cannot be moved close enough to the objective lens to be in focus. Place a tiny 

amount of oil (only 1 drop should be sufficient) onto the slide prior to rotating the 100XRD 

objective into position. It is essential to thoroughly clean the objective tip after use to prevent 

damage and to ensure that an image can be seen clearly the next time the objective is used. 

Please contact Motic Optical or your authorized Motic dealer for the appropriate immersion 

oil to use.

IMPORTANT:

 The working distances of the 40XRD and 100XRD objectives to the slide 

surface are very small and although these objectives are sealed to prevent oil contamination, 

it is a good practice to avoid dragging these objectives through an oiled slide. The 100XRD 

oil immersion lens on Motic microscopes has a spring-loaded end to prevent cracking the 

cover slip upon its initial contact. Once this zone of safety is exceeded by moving the slide 

further toward the lens, a point can be reached where damage will occur. Always make a 

practice of frequently checking the position of the lens on the slide. Note that a 100XRD 

objective requires an iris diaphragm for brightfield oil immersion microscopy.

Motic's patented POINTMASTER

®

 eyepiece reticle, which is installed in the eyepiece of the 

microscope, enables the user to easily measure the size of the specimen.

1. The numbers on the chart indicate the actual size of the POINTMASTER

®

 scale in millime-

ters. For example, the length is 1.0mm from the top of the arrow to the bottom; the total 

length of the scale is 8.0mm, etc. The thickness of all the horizontal lines is 0.01mm.

2. To obtain the actual physical size of a specimen, divide the POINTMASTER

®

 scale 

readings by the magnification of the objective lens that is in use. Divide the readings by 10 

if the 10X objective is being used, 40 if the 40XRD objective is in use, or 100 if of 100XRD 

is in use.

0.5

1.0

0.1

0.5

0.5

0.5

0.2

0.35

2.5

2.5

8.00

1.0

0.5

UNIT: mm  SCALE: 20/1

OIL IMMERSION

 For 100X objective

HOW TO USE THE POINTMASTER

®

 EYEPIECE RETICLE

Содержание 1100104800031

Страница 1: ...SILVER250 SERIES INSTRUCTION MANUAL ENGLISH SILVERLINE...

Страница 2: ...uch the optical lens surfaces WASTE DISPOSAL Important Any damaged biological microscope must not be treated as general waste it should be disposed of according to relevant regulations OPERATION When...

Страница 3: ...ive latent infective toxic radioactive or other hazardous samples Therefore when examin ing any such sample you must comply with the relevant laws and regulations in particular the provisions related...

Страница 4: ...SERIES 04 SILVER250 SERIES The SILVER250 Series stands out for its innovation quality and student proof features offering a wide range of microscopes for educational purposes in high schools up to adv...

Страница 5: ...he minimum position before turning on or off the power switch 4 Rotate the brightness control to the desired illumination 5 After use turn the brightness control to the minimum position and then turn...

Страница 6: ...itting properties as glass Using oil slight ly increases the resolution and brightness of the image Usually a very thin slide size 1 is used for oil immersion because at this magnification the working...

Страница 7: ...ll the correct driver IMPORTANT The next time you connect the SILVER250 Series microscope to a computer make sure the USB cable is connected to the same USB port that was used during initial installat...

Страница 8: ...for 0 17 transmitted light objective No immersion oil or non specified immersion oil for 100X oil immersion objective Aperture iris diaphragm is not set accurately Incorrect opening of aperture diaphr...

Страница 9: ...access the LED The LED is integrated on to a circuit board This LED circuit board is held into the illumina tor housing by 2 screws Remove the 2 screws from the illuminator housing to remove the LED c...

Страница 10: ...tube 30 20 Length of mechanical tube Maximum field number Hinge type interpupillary distance adjustment range Observation angle Infinite 20mm 48 to 75mm 30 Triocular tube 30 20 Length of mechanical t...

Страница 11: ...epair by unauthorized parties accident alteration shipping misuse or abuse is not covered Warranty service is provided by Motic authorized technicians Determination of warranty is at the technician s...

Страница 12: ...52 2882 2792 Motic Europe S L U Spain Pol gon Industrial Les Corts C Les Corts 12 08349 Cabrera de Mar Barcelona Spain Tel 34 93 756 6286 Fax 34 93 756 6287 CCIS is a trademark of Motic Incorporation...

Страница 13: ...he appropriate immersion oil to use IMPORTANT The working distances of the 40XRD and 100XRD objectives to the slide surface are very small and although these objectives are sealed to prevent oil conta...

Страница 14: ...f the glass The finish of the microscope is hard epoxy and is resistant to acids and reagents Clean this surface with a damp cloth and mild detergent Periodically the microscope should be disassembled...

Страница 15: ...view Is the Abbe condenser in the correct position Dust or hairs seem to be moving in the image The iris diaphragm is not open wide enough Slowly open the diaphragm to increase the size of the openin...

Отзывы: