Manual for compound,

monocular microscope

The compound microscope allows you to study,
at cell level, structures and textures of botanical
and zoological nature. (e.g. slides of roots,
leaves and stems or blood, skin and hairs).
Depending on the chosen microscope, the total
magnification lies between 40-1000 times. By
using different accessories, this magnification
can be expanded.
 

Applicable for: BMS 2, BMS 100 and BMS 200
series. 

For article numbers, see below.

1: Scope of delivery (numbers refer to the photo on page 5):

1) Eyepiece WF 10x, with pointer
2) Monocular tube 
3) Fixation screw to secure eyepiece
4) Microscope head, with prism. 360 º rotatable
5) Full metal stand
6) Full metal base with electrical parts and main lead.
7) Nose piece, revolving. Depending on model either triple or quadruple
8) Objectives, DIN Achromatic (with plastic containers)

4x/N.A. 0,10
10x/N.A. 0,25
40x/N.A. 0,65 spring loaded
100x/N.A. 1,25 spring loaded, oil immersion (only in models with quadruple 
nose piece)

9) Coarse adjustment with slip clutch
10)Tension adjustment on coarse knob (9)
11)Fine adjustment
12)Fuse
13)On-off switch
14)Lamp house with condenser lens
15)Iris diaphragm adjustable to 100% opening. Abbe condenser N.A. 1,25 (only

in models with quadruple nose piece)

16) Fixed condenser lens N.A. 0,65 (only in models with triple nosepiece).
17)Filter holder
18)Blue filter
19) Stage
20) Stage clips (stainless steel)
21) Adjustable slide protection
22)Wrench, to adjust tension on coarse adjustment (9)
23) Dust cover

Always disconnect mains plug from power point

before maintenance

Содержание BMS 2 series

Страница 1: ...al base with electrical parts and main lead 7 Nose piece revolving Depending on model either triple or quadruple 8 Objectives DIN Achromatic with plastic containers 4x N A 0 10 10x N A 0 25 40x N A 0 65 spring loaded 100x N A 1 25 spring loaded oil immersion only in models with quadruple nose piece 9 Coarse adjustment with slip clutch 10 Tension adjustment on coarse knob 9 11 Fine adjustment 12 Fu...

Страница 2: ... 20 and secure the slide Make sure the objective with the smallest magnification 4x is above the slide Use coarse adjustment 9 to focus the specimen After this the fine adjustment 11 is used to refine the image By revolving the nose piece and bring another objective in the path of light a different total magnification will be reached If magnification is increased step by step revolving nose piece ...

Страница 3: ...the large flat screw and tighten it 5 Replacing fuse 12 Not applicable for LED CIS and Art Nr 76013 76016 Read point 3 Safety notes carefully Wait until the temperature of the microscope and electrical parts are cool The fuse is located on the back of the stand 76002 76010 76014 76015 76017 76018 76019 76021 Use a screw driver to open the housing of the fuse by turning it counter clockwise Take br...

Страница 4: ... x 76053 Blue filter x x x 76054 Dust cover x x x 76070 Polarisation set x x x 76031 Carrying case wood x x x not suited for mentioned models x for all models This manual is applicable for series and models with following article numbers BMS 2 series 76000 and 76002 BMS 100 series 76005 76007 76008 76009 76010 76012 76013 76014 76017 76018 76019 76021 BMS 200 series 76015 76016 BMS 1001FL Jubilee ...

Страница 5: ...____ 8______________________________ 20_______________________________________ ____________________ 21 16______________________________________ 19______________________________ 15_________________________________ ______________ 10 9________________________________________________ 14___________________________________ _______________ 11 13_____________________________ ___________ 6 ________ 12 BMS ...

Отзывы: