3.6.5.1.2. TS PreAlm-Level:
The value of DC pre-alarm level in percents of DC main alarm.
Possible values: 40 to 100.
3.6.5.1.3. RPM Alarm-Level:
The value of overspeed alarm in RPM. Possible values: 0 to 3000, step 50.
The 0 value disables the alarm.
3.6.5.1.4. TS Alm-Level1 AC:
The value of AC main alarm level in the RPM zone 1. Possible values: 0 to 5.
The 0 value disables the alarm.
3.6.5.1.5. TS Alm-Level2 AC:
The value of AC main alarm level in the RPM zone 2. Possible values: 0 to 5.
The 0 value disables the alarm.
3.6.5.1.6. RPM for Level2:
Engine rotation speed in RPM which defines the boundary between RPM zone 1
and RPM zone 2.
3.6.5.1.7. Start Alminhibit:
Time interval in seconds immediately after engine start during which the main alarm
is disabled.
3.6.5.1.8. TS Test Time:
Time interval between test pulses, possible values: 1 min to 10 min. Test pulses
help to check if the SRE sensor functions correct.
3.6.5.1.9. TS Test Len:
The length of test pulse. Possible values: 1 s to 15 s.
3.6.5.1.10. IS Impuls Offset:
The offset between TDC of cylinder 1 and the synchronisation pulse at the
channel 0.
This value cannot be set at the Evaluator using the “Up” and “Down” buttons. It is
used during the impulse offset setup procedure as an indicator.
To start the procedure, a special PIN must be entered (see
chapter 3.6.5.1.11.,
page 3.13)).
Содержание BeCOMS BCom
Страница 2: ......
Страница 6: ...motcom BeCOMS BCom User Manual Release 130301 revision 190211 Page vi...
Страница 50: ...motcom BeCOMS BCom User Manual Release 130301 revision 190211 Page 3 22...
Страница 52: ...motcom BeCOMS BCom User Manual Release 130301 revision 190211 Page 4 2...
Страница 60: ...motcom BeCOMS BCom User Manual Release 130301 revision 190211 Page 6 2...
Страница 68: ...motcom BeCOMS BCom User Manual Release 130301 revision 190211 Page 7 8...
Страница 81: ...motcom BeCOMS BCom User Manual Release 130301 revision 190211 Page 8 13 Fig 8 14 BCom Evaluator...