STARTING THE ENGINE
REV.0-09/07
TS 350 YSX BC
M
21
Temperature
Time
≤
- 20° C
to - 20° C from -10°C
to - 10° C from -5°C
≥
5° C
5 min.
2 min.
1 min.
20 sec.
RUNNING-IN
During the first 50 hours of operation, do not use more than
60% of the maximum output power of the unit and check the
oil level frequently, in any case please stick to the rules given
in the engine use manual.
CAUTION
Do not alter the primary conditions of regulation and do not
touch the sealed parts.
NOTE
!
Check daily
!
ATTENTION
1
. By start-up of the generator the welding circuit
is immediately operative, i.e. under voltage.
Make sure that there are no unwished electrical
contacts between the components of the outside
welding circuit (electrode, electrode holder gun,
workpiece, etc…).
2.
Check that at the start-up the a.c. auxiliary ge-
neration sockets do not feed any load.
Open the electric protection interrupter
of the generator or disconnect the plugs
of the loads from the sockets.
3.
START-UP
Remember that when the machines with auto-idle
have the signal set to “auto-idle” will remain at
the minimum no. of revs (tickover) as long as no
current is drawn.
Drawing power will automatically raise the
number of engine revs to the nominal value and
likewise the tension in the alternator.
Instead, by setting the auto-idle signal to “max”,
the engine revs will immediately rise to the nomi-
nal value and likewise the tension in the alterna-
tor.
For the machines with manual accelerator, it is
necessary to accelerate the motor manually in
order to reach the nominal tension.
Starting is actuated using the key which is an
integral part of the EP7 post on the front panel.
A) - Turn the key in a clockwise direction until all the
LED lights are illuminated.
B) - Wait until the “OIL PRESSURE” and “BATTERY
VOLTAGE” LEDs remain illuminated. If the timer
lamp is used, the yellow “PREHEAT” LED co-
mes on for the set time of the imposed settings.
C) - As soon as the green “ENGINE RUNNING”
LED starts to flash, actuate the key switch in a
clockwise direction (momentarily in the position
then with return to rest) until obtaining starting
of the engine.
If the motor does not start within 15 seconds, the
non starting alert will intervene: the two LEDs
“Engine running” and “glow plug” will flash al
-
ternately (see motor protection description).
D) - At any time it is possible to stop the engine by
turning the key in an anti-clockwise direction
(OFF position).
In case of engine anomaly due to low oil pres-
sure, high temperature, broken transmission
belt, low fuel level or emergency the EP7 will
automatically stop the engine.
4.
The machines with auto-idle tickover at a mini-
mum of 2400- 2500 rpm. After starting, allow the
engine to run for a few minutes before drawing
any charge, see the related table below.
The machines with a manual accelerator tickover
at around 2000 rpm. Also in this case, respect the
warm up period in the table.
12/1
1/07 87381-GB
5.
start-up at low temperatures.
The motor will normally start up without problems
down to temperatures of -10° C, -15° C. In case
of starting difficulty, it is possible to repeat the
starting preheating for a max. time of 10 second,
lightly turning the trimmer situated at the back
of the EP7 in a clockwise direction (see page
M39.13 relating to engine protection “trimmer/
glow plug”). For start-up and use at lower tem-
peratures please see the engine manual or turn
to our Technical Assistance Center.
In case of unsuccessful start-up, do not in-
sist for longer than 5 seconds. Wait 10 - 15
seconds before attempting another start-up.
!