STARTING AND STOPPING THE ENGINE
GE 7000 HBSL/ HBSLE - AVR
GE 7500 HBSL/ HBSLE - AVR
M
26
REV.0 - 05/14
I
GB
F
to check before every starting
19/05/14 25770-GB
STARTING THE ENGINE
3)
Easy Start
The engine is equipped with a pneumatic air system
(choke) called Easy Start that allows you to start the
engine without choke adjustment when the ambient
temperature is between 10° C and 25° C.
In these conditions leave the choke rod in its mid-
position, work position.
At temperatures below the indicated pull the rod in
the CLOSED position, start the engine and gradually
push the rod in the position of work while the engine
warms up.
To start a warm engine, push the
rod choke in the OPEN position.
Once the engine is started up move
the rod in the work position.
1) make sure the load plugs are
disconnected or that the main
switch of machine is open (lever
facing down), so as to ensure
the motor’s start-up without any
loads inserted.
2) Open the gosoline cock
MANUAL RECOIL
ON
ON
ENGINE SWITCH
ENGINE SWITCH
OFF
4) Turn the engine switch to the ON
position.
5) hold the starting handle properly
and pull slowly until you feel resi-
stance
6) then return it slowly
RUNNING-IN
During the first 50 hours of operation, do not use
more than 60% of the maximum output power of
the unit and check the oil level frequently.
CAUTION
!
CLOSED
OPEN
CHOKE ROD
7) pull the rope hard and fast. Pull it all the
way out. Use two hands if necessary.
Electric start
4) Turn the start-up key (Q1) to the ON
position.
5) Turn the start-up key (Q1) to the START
position, once the engine is started up
leave the key, it will reposition itself in
“ON”.
+
In case of unsuccessful start-up, do not insist for
longer than 5 seconds. Wait 10 seconds before
attempting another start-up.
6) If the choke rod was moved to the
CLOSED or OPEN position to start
the engine, once the engine is
started up move the rod in the work
position.
7) Warm up the engine for 2 or 3 minu-
tes.
STOPPING THE ENGINE
To stop the engine in an emergency,
simply turn the engine switch to the OFF
position.
Under normal conditions, use the following
procedure:
1) stop the power source, turning off the
connected equipment, if they do not
have a power switch, open the main
switch of the machine (lever facing
down)
2) allow the engine to run without any load
for a few minutes
3) Turn the engine switch or the starter
key to the OFF position
4) Shut the gasoline cock.
CLOSED
OPEN
CHOKE ROD
Do not alter the primary conditions of regulation and do
not touch the sealed parts.
NOTE
!