![Mosa GE 7000 KDes-gs Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/mosa/ge-7000-kdes-gs/ge-7000-kdes-gs_use-and-maintenance-manual_1836878010.webp)
31/01/13 25654-I
GE 7500 HBSL-AVR
GE 7500 HBSLE-AVR
M
1.5
REV.0 - 05/14
I
GB
F
TECHNICAL DATA
Technical data
GE 7500 HBSL-AVR
GE 7500 HBSLE-AVR
GENERATOR
Stand-by three-phase power
8 kVA (6.4 kW) / 400V / 11.5 A
PRP three-phase power
7 kVA (5.8 kW) / 400V / 10.1 A
PRP single-phase power
3 kVA / 230V / 13 A
Frequency
50 Hz
Cos
ϕ
0.8
* Output powers according to ISO 8528-1
ALTERNATOR
self-excited, self-regulated
Type
three-phase, synchronous
Insulation class
H
ENGINE
Make / Model
HONDA GX 390
Type / Cooling system
Gasoline 4-Stroke / air
Cylinder / Displacement
1 / 389 cm
3
*Stand-by net power
8.2 kW (11.1 HP)
**PRP net power
6.4 kW (8.7 HP)
Speed
3000 rpm
Fuel consumption (75% of PRP)
2.4 l/h
Engine oil capacity
1.1 l
Starter
Recoil
Electric
* Powers according to ISO 3046-1
GENERAL SPECIFICATIONS
Tank capacity
25 l
Running time (75% of PRP)
10.4 h
Protection
IP 23
*Dimensions / max. on base Lxwxh
750x520x660
*Weight on base
93 Kg
104 Kg
Measured acoustic power Lwa (pression LpA)
96 dB(A) (71 dB(A) @ 7 m)
Garanteed acoustic power Lwa (pression LpA)
96 dB(A) (71 dB(A) @ 7 m)
* Dimensions and weight are inclusive of all parts.
2000 / 14 / CE
OUTPUT
Declared power according to ISO 8528-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
(*Stand-by) = maximum available power for use at variable loads for a yearly number of hours limited at 500 h. No overload is
admitted.
(**Prime power PRP) = maximum available power for use at variable loads for a yearly illimited number of hours. The average
power to be taken during a period of 24 h must not be over 80% of the PRP.
It’s admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION:
The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level (L
W
A
)
- Measure Unit dB(A):
it stands for acoustic noise released in a certain delay of time. This is not
submitted to the distance of measurement.
Acoustic Pressure (Lp)
- Measure Unit dB(A):
it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(
L
W
A
) of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE:
the symbol when with acoustic noise values, indicates that the device respects noise emission limits
according to 2000/14/CE directive.
2000 / 14 / CE