To insure the best performance, optimal efficiencies and heat output of the heating unit, it is
recommended and necessary to become familiar with your unit and the procedures needed
with initially starting, running, cleaning and maintaining the heating unit.
It is important to remember when burning used or dirty oils that contaminants could be
present. Because of various contaminates, be aware of needing to change filters when
needed. Keep the chamber and heat exchanger(s) passageways clean. Make sure the fuel
pump is primed and lines are free of any debris, air bubbles or interuptions.
Draft is just as important as the rest; bad draft can cause serious problems and not allow the
gasses within the unit to correctly leave the heating unit. Correct draft is needed for optimal
performance. Bad draft will cause over-fire or overheating due to bottling up the heat or
creating back pressure back in to the heating unit. If black smoke is present, bad draft, bad
combustion or both is occuring.