TriStar MPPT 600V Operator’s Manual

8

Important Safety Instructions

•  Servicing of batteries should be performed, or supervised, by personnel knowledgeable about    

batteries, and the proper safety precautions. 

•   Be very careful when working with large lead-acid batteries. Wear eye protection and have fresh 

water  available in case there is contact with the battery acid.

•  Remove watches, rings, jewelry and other metal objects before working with batteries.
•  Wear rubber gloves and boots

•  Use tools with insulated handles and avoid placing tools or metal objects on top of batteries.

•  Disconnect charging source prior to connecting or dis-connecting battery terminals.

•  Determine if battery is inadvertently grounded.  If so, remove the source of contact with ground.  

Contact with any part of a grounded battery can result in electrical shock.  The likelihood of such 

a shock can be reduced if battery grounds are removed during installation and maint enance    

(applicable to equipment and remote battery supplies not having a grounded supply circuit).

•  Carefully read the battery manufacturer’s instructions before installing / connecting to, or removing 

batteries from, the TriStar MPPT 600V.

•  Be very careful not to short circuit the cables connected to the battery. 

•  Have someone nearby to assist in case of an accident.
•  Explosive battery gases can be present during charging. Be certain there is enough ventilation to 

release the gases.

•  Never smoke in the battery area.
•   If battery acid comes into contact with the skin, wash with soap and water. If the acid contacts the 

e e oo

it res

ater an

et e ica attention

•  Be sure the battery electrolyte level is correct before starting charging. Do not attempt to charge a frozen 

battery. 

•  Recycle the battery when it is replaced.

•  Entretien des batteries devrait être effectué ou supervisé, par un personnel bien informé sur les 

piles et les précautions de sécurité appropriées.

•  Soyez très prudent quand vous travaillez avec des grandes batteries au plomb. Portez des lunettes 

de protection et ayez de l’eau fraîche à disposition en cas de contact avec l’électrolyte.

•   Enlevez les montres, bagues, bijoux et autres objets mé talliques avant de travailler avec des piles.
•  Porter des bottes et des gants de caoutchouc 
•   Utiliser des outils avec poignées isolantes et évitez de placer des outils ou des objets métalliques 

sur le dessus de batteries.

•  Débrancher la source de charge avant de brancher ou  dis-reliant les bornes de la batterie.
•  Utilisez des outils isolés et évitez de placer des objets métalliques dans la zone de travail.
• 

ter iner si atterie re ose ar ina ertance ans a fir ati e s

ri er a so rce

contact

avec le sol. Contact avec n’importe quelle partie d’une batterie mise à la terre peut entraîner un 

choc électrique. La probabilité d’un tel choc peut être réduite si des motifs de batterie sont suppri-

més pendant l’installation et maintentretien (applicable à l’équipement et les fournitures de pile de 

la télécommande n’ayant ne pas un circuit d’alimentation mise à la terre *).

•  Lisez attentivement les instructions du fabricant de la batterie avant d’installer / connexion à ou 

retrait des batteries du TriStar MPPT 600V.

•  Veillez à ne pas court-circuiter les câbles connectés à la batterie.
•  Ayez une personne à proximité qui puisse aider en cas d’accident.

•   Ce contrôleur de charge ne doit être connecté qu’à des circuits en courant continu. Ces connex-

ions CC sont i entifi es ar e s

o e ci esso s

e contr e r ri tar

oit tre insta

ar n tec nicien

a ifi con or

-

ment aux   règlementations électriques du pays où est installé le produit.
Un moyen d’assurer la déconnexion de tous les pôles de l’alimentation doit être fourni.  Cette décon-

ne ion oit tre incor or e ans e c

a e fi e

À l’aide de la borne de mise à la masse du TriStar MPPT 600V 600V600V (dans le compartiment de 

c

a e

n o en er anent et fia e e ise

a terre oit tre o rni

a fi ation e a ise

a

terre oit tre fi e contre to t esserra e acci ente

Les  ouvertures  d’entrée  au  compartiment  de  câblage  du  TriStar  MPPT  600V  600V600V  doivent  être               

protégées avec un conduit ou une bague.

Battery Safety

WARNING:

 

A battery can present a risk of electrical  shock or burn from large amounts 

                of short-circuit   current, fire, or explosion from vented gases.  Observe proper precautions.

              

AVERTISSEMENT: 

 

Une batterie peut présenter a ris que de choc électrique ou de brûlure 

 

     de grandes  quantités de court-circuit curlouer, incendie ou explosion de ventilé gaz.        

 

     Observer  précautions appropriées.

     

    

WARNING:  Risk of Explosion.

 

    

Proper disposal of batteries is required.  Do not dispose of batteries in fire.  Refer to 

 

     local regulations or codes for requirements.

 

     

AVERTISSEMENT:  Risque d’Explosion.

                

Au rebut des piles est nécessaire. Ne pas jeter les piles dans le feu. Se référer aux régle 

 

      mentations locales ou des codes pour les exigences.

CAUTION:

  

When replacing batteries, proper specified number, sizes types and ratings 

 

    based on application and system design

                 

PRUDENCE:

  

Lorsque le remplacement des piles, utilisez correctement nombre spécifié,   

 

     tailles, types et   les évaluations basées sur conception de système et   d’application.

CAUTION: 

 

Do not open or mutilate batteries.  Released electrolyte is harmful to skin,  

 

    and may be  toxic.

                 

PRUDENCE:

  

Ne pas ouvrir ou mutiler les piles.  L’électrolyte est nocif pour la peau et  

 

      peut être  toxique.

Содержание TRISTAR TS-MPPT-60-600V-48

Страница 1: ...www morningstarcorp com Solar Battery Charger with TrakStarTM Maximum Power Point Tracking Technology MODELS TS MPPT 60 600V 48 TS MPPT 60 600V 48 DB MAXIMUM POWER POINT TRACKING TRISTAR MPPT 600V TM...

Страница 2: ...Conduit Knock outs and Wiring Routing 21 3 4 Controller Preparation 23 3 5 Mounting 26 3 6 Network Connections 28 3 7 Wiring Connections 30 Confi ration 3 9 Power Up Commissioning 41 4 0 Operation 42...

Страница 3: ...tion of the controller AVERTISSEMENT Indique une condition potentiellement dangereuse Faites preuve d une prudence extr me lors de la r alisation de cette t che PRUDENCE Indique une proc dure critique...

Страница 4: ...terre se tro e ans e co arti ent e c a e et est i entifi e ar e symbole ci dessous estampill dans le boit Informations de S curit ise to tes es instr ctions et es a ertisse ents fi rant ans e an e a a...

Страница 5: ...a zone de travail ter iner si atterie re ose ar ina ertance ans a fir ati e s ri er a so rce contact avec le sol Contact avec n importe quelle partie d une batterie mise la terre peut entra ner un cho...

Страница 6: ...provided to ensure all pole disconnection from the power supply This isconnection s a e incor orate in t e fi e irin Using the TriStar MPPT 600V grounding terminal in the wiring compartment a permanen...

Страница 7: ...nt or re locate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connecte...

Страница 8: ...RS 232 Port 9 pin serial connector female 8 EIA 485 Port Four 4 position screw terminal for EIA 485 bus connections 9 Ground Terminals 2 total A chassis ground terminal for equipment grounding 10 Bla...

Страница 9: ...site at www morningstarcorp com or inquire with your local Morningstar dealer EIA 485 RS 232 Communications Adapter RSC 1 Connect one or more TriStar MPPT 600V controllers to a PC or to other serial d...

Страница 10: ...in the system These protection devices are external to the TriStar MPPT 600V controller and must be a maximum of 90 amps for the TriStar MPPT 600V Maximum battery short circuit current rating must be...

Страница 11: ...PPT 600V wiring box Knockout place ment dimensions are on the inside front cover Figures 3 2 to 3 5 show knock out types The TriStar MPPT 600V wiring box provides continuous and separate paths for hig...

Страница 12: ...1 2 or M20 0 88 22 2 mm Battery low voltage NO 11 2 3 4 1 09 27 8 mm Solar high voltage NO 12 2 1 1 36 34 5 mm Battery low voltage NO Solar connector mounting hole diameters vary Wieland Solar DC con...

Страница 13: ...ider is secured with only one screw 1 Use a 2 Philips screw driver to remove the screw 2 Lift and tilt the divider towards the bottom of the unit as shown in Figure 3 8 3 Lift the divider out of the w...

Страница 14: ...oller may be insta e in a enti ate enc os re it s ficient air o e er insta t e ri tar in a sealed enclosure The controller may be mounted in an enclosure with sealed batteries but never it ente oo e a...

Страница 15: ...section 5 0 for more information about networking and the connection s required for your system WARNING Shock Hazard Only route network cables in the same conduit as the photovoltaic power conductors...

Страница 16: ...ss of 500 Vdc when in sunlight Verify that the solar input breaker or disconnect has been opened disconnected before installing the system wires AVERTISSEMENT Risque de d charge lectrique Le r seau PV...

Страница 17: ...hat the battery connection is made with correct polarity Turn on the battery breaker disconnect and measure the voltage on the open battery wires BEFORE connecting to the TriStar MPPT 600V Disconnect...

Страница 18: ...recte dans le cas contraire subira des dommages Activez le coupe circuit interrupteur de la batterie et mesure la tension sur les c bles ouverts AVANT la connexion au TriStar MPPT 600V D connectez le...

Страница 19: ...ferrite sur l extr mit du RTS si une longueur de c ble est enlev e Cette bobine assure la conformit avec les normes d missions lectromagn tiques Step 8 Battery Voltage Sense The voltage at the batter...

Страница 20: ...ation will only occur when manually started with the push button or when requested from the equalize menu on the TriStar meter Automatic equalization will occur accor in to t e atter ro ra s ecifie se...

Страница 21: ...seul point 3 9 Power up and Commissioning Step 11 Power Up TS MPPT 60 600V 48 and TS MPPT 60 600V 48 DB WARNING Risk of Damage Connecting the solar power source to the battery terminal will permanent...

Страница 22: ...the ability to charge batteries with power sources of higher nominal voltages The TriStar MPPT 600V charges a 48 Volt battery bank with a high voltage power source The power source open circuit volta...

Страница 23: ...e syst me Certain atter t es enefit ro a erio ic oost c ar e to stir t e e ectro te e e t e ce o t ages and complete the chemical reactions Equalize charging raises the battery voltage above the stand...

Страница 24: ...inal 48 Volt battery banks Settings Switches 4 5 6 Battery Type Absorp Stage Volts Float Stage Volts Equalize Stage Volts Absorp Time Minutes Equalize Time Minutes Equalize Interval Days off off off 1...

Страница 25: ...sly for 60 min However because the Float exit timer is cumulative multiple momentary load events that pull the battery voltage below Float voltage for a combined 60 minutes duration will also force an...

Страница 26: ...improve the accuracy of the battery charging See Section 3 4 Step 8 for instructions on how to connect the battery sense wires 4 3 Push button The following functions can be enabled with the pushbutt...

Страница 27: ...Absorption G blinking once per second Equalization state G fast blink two times per second Float state G slow blink once per two seconds Faults Alarms Over temperature Y R sequencing High voltage disc...

Страница 28: ...ndicate a failure If the control ler is restarted with the failure still present the controller may not detect that the battery sense is connected and the LEDs will not indicate a fault A TriStar mete...

Страница 29: ...not factory calibrated Return the controller to an authorized Morningstar dealer for service 5 0 Networking and Communication 5 1 Introduction The TriStar MPPT 600V provides several communication opti...

Страница 30: ...ollers Figure 5 1 An example MeterBus network to fi e contro ers can e net or e to et er it a sin e ti e s can e daisy chained together to allow networks of up to 15 controllers and 2 meters Refer to...

Страница 31: ...twork with custom charge settings using MSViewTM PC software connect the TriStar MPPT 600V to other Morningstar controllers with the RSC 1 Serial to EIA 485 Adapter sold separately bridge an Ethernet...

Страница 32: ...tion about Ethernet connectivity and networking refer to the Morningstar Communications Document on our web site at HTTP www morningstarcorp com Network Information Connect to the TriStar MPPT 600V vi...

Страница 33: ...contro er can e confi re to o a itiona o tion al values each day The maximum number of days that can be stored decreases as the number of logged values increases Standard Values Minimum Battery Volta...

Страница 34: ...ence see Section 4 4 Faults Alarms of this manual to determine the cause If a TriStar Meter 2 600V is connected the diagnostics menu will display reported faults and alarms Troubleshooting 6 0 If the...

Страница 35: ...n of the controller AVERTISSEMENT Indique une condition potentiellement dangereuse Faites preuve d une prudence extr me lors de la r alisation de cette t che PRUDENCE Indique une proc dure critique po...

Страница 36: ...nts casual contact The TriStar MPPT 600V heatsink can become very hot during operation Use insulated tools when working with batteries Avoid wearing jewelry during installation The battery bank must b...

Страница 37: ...vrir ou mutiler les piles L lectrolyte est nocif pour la peau et peut tre toxique Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and the proper saf...

Страница 38: ...k Hazard Disconnect all power sources to the controller before removing the wiring box cover Never remove the cover when voltage exists on the TriStar MPPT 600V power connections AVERTISSEMENT Risque...

Страница 39: ...MAGES OF ANY KIND INCLUDING BUT NOT LIMITED TO LOST PROFITS DOWN TIME GOODWILL OR DAMAGE TO EQUIPMENT OR PROPERTY R15 8 18 Warranty and Claim Procedure 8 0 WARRANTY CLAIM PROCEDURE 1 Before proceeding...

Страница 40: ...aled 56 60 54 80 57 60 150 60 120 28 off on off 3 Sealed 57 20 54 80 58 40 150 60 120 28 off on on 4 AGM Flooded 57 60 54 80 60 40 180 120 180 28 on off off 5 Flooded 58 40 54 00 61 20 180 120 180 28...

Страница 41: ...ndoor vented Protections Solar High Voltage Disconnect Solar High Voltage Reconnect Battery High Voltage Disconnect Battery High Voltage Reconnect High Temperature Disconnect High Temperature Reconnec...

Страница 42: ...60 Amp Battery Current Limit 60 Amp Battery Current Limit Vb 60 V 0 100 200 300 400 500 600 500 1000 1500 2000 2500 3000 3500 INPUT VOLTAGE Volts POWER Watts Output Power vs Array Input Voltage Figur...

Страница 43: ...6 8 8 1 10 2 13 6 6 2 1 2 3 2 6 2 8 3 2 3 7 4 3 5 1 6 4 8 5 4 1 3 1 5 1 6 1 8 2 0 2 3 2 7 3 2 4 0 5 3 2 5 0 8 0 9 1 0 1 1 1 3 1 4 1 7 2 0 2 5 3 4 Table 9 2 Maximum 1 way wire distance for 48V systems...

Страница 44: ...ty at 50 C ambient temperature Exceeds wire ampacity at 40 C ambient temperature Exceeds wire ampacity at 30 C ambient temperature Ampacity for not more than three current car rying conductors in a ra...

Страница 45: ...o con ctors ro t e so ar or atter so rce to t e controller 1 way distance Shaded cells in the table indicate that the current exceeds the ampacity of the wire for a i en a ient te erat re as efine in...

Отзывы: